Haier E6 — Dishwasher
[ACTIVE]Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Controller EEPROM memory error E6; microcomputer detects corrupted configuration checksum or unprogrammed module.
On Haier dishwashers utilizing I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: AC mains voltage spike, corrupted non-volatile memory cell on PCB, or unprogrammed replacement board installed.
Power down machine at isolation switch for 10 minutes. If error persists, enter service mode and re-enter model code, or replace main control board. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.