Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEER03
Haier
Haier // OFFICIAL DIAGNOSTIC BENCH

Haier Hob ER03

HobWater Level Pressure Switch & Air Dome
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Hob
Select Appliance Type
0ms Instant Telemetry Switch
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
CandyER03HooverER03RosièresER03ZerowattER03IbernaER03GEER03
Other Brands Sharing Code ER03:BrandtER03De DietrichER03FAGORER03SauterER03ScholtèsER03AirluxER03ArdoER03

Symptom / Description

FAULT

Haier I-Move Series / Multi Switch Precision Induction Hob: Permanent touch key activation alarm ER03; liquid spill or cookware resting continuously on sensor controls.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Heavy liquid overflow across touch buttons, conductive sauce splatter, or pan overhang onto glass touch zone.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Remove all pots and utensils from glass. Sponge up all liquids and dry touch area thoroughly with a clean microfiber cloth. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Haier Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Nominal Resistance / Test Range
Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.
Test Harness Pins
Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Level Pressure Switch & Air DomeHob / Cooktop
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Test Pins & Connections
PROBE (+)
PROBE (-)
Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal
Tolerance & Diagnostic CriteriaMechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Cut 230V mains power before accessing the upper chassis or pressure switch terminals.
  • !Drain appliance tub completely before disconnecting pressure switch sensing hoses.
  • !Never blow high-pressure compressed air into electronic analog pressure sensors: internal diaphragms will rupture!
3. Preliminary Mechanical & Visual Checks
  • Disconnect the silicone pressure tube from the lower air trap and inspect for soap sludge, lint, or water blockage.
  • Inspect the flexible rubber hose along its entire length for pinholes, cracks, or loose clamp fit.
  • Thoroughly flush the lower compression chamber (air dome) with hot water to dissolve detergent buildup.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Haier ER03

FAQ TREE
What does error code ER03 mean on a Haier appliance?

Haier error code ER03 indicates: Haier I-Move Series / Multi Switch Precision Induction Hob: Permanent touch key activation alarm ER03; liquid spill or cookware resting continuously on sensor controls..

What is the root cause of Haier error code ER03?

The primary root cause for Haier code ER03 is: On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Heavy liquid overflow across touch buttons, conductive sauce splatter, or pan overhang onto glass touch zone..

How do I fix or resolve Haier error code ER03?

To resolve error code ER03: Remove all pots and utensils from glass. Sponge up all liquids and dry touch area thoroughly with a clean microfiber cloth. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.

Is it safe to clear Haier error code ER03 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Haier code ER03 persists, the physical component causing On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Heavy liquid overflow across touch buttons, conductive sauce splatter, or pan overhang onto glass touch zone. must be inspected or replaced.

How do I test electrical resistance for Haier code ER03 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..

What safety protocol must be followed before servicing Haier code ER03?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Haier error code ER03 mean on a Hob?

Haier error code ER03 on a Hob indicates: Haier I-Move Series / Multi Switch Precision Induction Hob: Permanent touch key activation alarm ER03; liquid spill or cookware resting continuously on sensor controls.. Primary cause: On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Heavy liquid overflow across touch buttons, conductive sauce splatter, or pan overhang onto glass touch zone.. Recommended solution: Remove all pots and utensils from glass. Sponge up all liquids and dry touch area thoroughly with a clean microfiber cloth. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds..

What does Haier error code ER03 mean on a Oven?

Haier error code ER03 on a Oven indicates: Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.. Primary cause: On Haier ovens featuring Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Welded heating element relay contacts on power board keeping elements energized continuously, or defective probe.. Recommended solution: Disconnect power breaker immediately. Allow oven to cool down completely. Test heating element relay contacts on power PCB for short circuit. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Haier ER03 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Haier ER03 — Hob

[ACTIVE]
Symptom / Description:

Haier I-Move Series / Multi Switch Precision Induction Hob: Permanent touch key activation alarm ER03; liquid spill or cookware resting continuously on sensor controls.

Root Cause:

On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Heavy liquid overflow across touch buttons, conductive sauce splatter, or pan overhang onto glass touch zone.

Repair Instructions:

Remove all pots and utensils from glass. Sponge up all liquids and dry touch area thoroughly with a clean microfiber cloth. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.

Haier ER03 — Oven

Symptom / Description:

Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.

Root Cause:

On Haier ovens featuring Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Welded heating element relay contacts on power board keeping elements energized continuously, or defective probe.

Repair Instructions:

Disconnect power breaker immediately. Allow oven to cool down completely. Test heating element relay contacts on power PCB for short circuit. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.

SEMANTIC KNOWLEDGE GRAPH // HAIER

Related Haier Hob / Cooktop Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

ER20Hob
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Microcontroller flash / EEPROM c...
Inspect Protocol
ER21Hob
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Ambient electronics housing temp...
Inspect Protocol
ER22Hob
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch control evaluation hardwar...
Inspect Protocol
ER31Hob
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Power board configuration data c...
Inspect Protocol
ER36Hob
NTC Temperature Sensor & Thermistor
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch board ambient NTC sensor s...
Inspect Protocol
ER47Hob
Drive Motor, Inverter & Tachometer Sensor
Haier I-Move Series / Multi Switch Precision Induction Hob: LIN-Bus communication between to...
Inspect Protocol
F0Hob
NTC Temperature Sensor & Thermistor
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor ...
Inspect Protocol
F1Hob
NTC Temperature Sensor & Thermistor
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor ...
Inspect Protocol
F2Hob
Drive Motor, Inverter & Tachometer Sensor
Haier I-Move Series / Multi Switch Precision Induction Hob: Communication loss to induction ...
Inspect Protocol
F7Hob
Drive Motor, Inverter & Tachometer Sensor
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply frequency out of li...
Inspect Protocol
F8Hob
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Continuous heating safety timer ...
Inspect Protocol
F9Hob
Heating Element, Thermostat & Safety Fuse
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil current sensor ca...
Inspect Protocol
UHob
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply undervoltage / phas...
Inspect Protocol
E0Hob
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch control module initializat...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy