Haier F6 — Dryer
[ACTIVE]Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected.
On Haier dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Foreign object or fluff obstructing fan blades, open fan motor winding (~200–500 Ω), or failed drive circuit.
Inspect cooling fan in lower compressor bay. Ensure fan blade spins freely without rubbing. Measure fan motor coil resistance (~200–500 Ω). Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.