Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE02
Hoover
Hoover // OFFICIAL DIAGNOSTIC BENCH

Hoover Dishwasher E02

DishwasherWater Inlet Valve, Aquastop & Flowmeter
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
HaierE02CandyE02RosièresE02ZerowattE02IbernaE02GEE02
Other Brands Sharing Code E02:BoschE02SiemensE02SamsungE02LGE02ElectroluxE02AEGE02BekoE02NeffE02

Symptom / Description

FAULT

Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Hoover dishwashers featuring H-DISH Maxi Tub architecture, Triple Self-Cleaning micro-filtration wash system, and hOn Wi-Fi connectivity: Magnet pin loose in flowmeter impeller, limescale accumulation inside water jacket labyrinth, or oxidized plug contacts.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Inspect left-side plastic air break for scale deposits. Clean electrical contacts on reed switch PCB with contact spray. Replace air break if impeller sticks. Hold the Programme selector button and Start/Pause together for 6 seconds until all indicator LEDs light up, then power off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Hoover Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Water Inlet, Aquastop & Flowmeter Loop

Inlet Solenoid Valve Y1, Reed Turbine Flowmeter & Aquastop Float S2

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III3.84 kΩVΩCOMINLET VALVE Y1SOLENOID Y1: 4.0 kΩFLOWMETER B1 (REED)AQUASTOP SWITCH S2: 0.0Ω
Target Component
Solenoid Valve Coil / Aquastop Pneumatic Valve
Nominal Resistance / Test Range
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)
Test Harness Pins
Across coil spade terminals (disconnect harness first)
Diagnostic Verification Rule
OL on solenoid indicates open coil. Closed contact on float switch S2 indicates base pan leak.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Inlet Valve, Aquastop & FlowmeterDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Solenoid Valve Coil / Aquastop Pneumatic Valve
Test Pins & Connections
PROBE (+)
PROBE (-)
Across coil spade terminals (disconnect harness first)
Tolerance & Diagnostic Criteria±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical power before touching solenoid valve coils or Aquastop connectors.
  • !Firmly shut off the domc water supply tap before unscrewing the inlet hose fitting.
  • !Check safety base drip tray for accumulated water triggering the anti-flood polystyrene float switch.
3. Preliminary Mechanical & Visual Checks
  • Remove and clean sediment and sand particles from the 3/4" inlet hose metal mesh filter.
  • Verify domestic dynamic water pressure is between 1.0 and 10.0 bar (0.1 to 1.0 MPa).
  • Inspect outer Aquastop hose jacket for expansion, pinch damage, or internal leak reservoir triggering.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Hoover E02

FAQ TREE
What does error code E02 mean on a Hoover appliance?

Hoover error code E02 indicates: Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out..

What is the root cause of Hoover error code E02?

The primary root cause for Hoover code E02 is: On Hoover dishwashers featuring H-DISH Maxi Tub architecture, Triple Self-Cleaning micro-filtration wash system, and hOn Wi-Fi connectivity: Magnet pin loose in flowmeter impeller, limescale accumulation inside water jacket labyrinth, or oxidized plug contacts..

How do I fix or resolve Hoover error code E02?

To resolve error code E02: Inspect left-side plastic air break for scale deposits. Clean electrical contacts on reed switch PCB with contact spray. Replace air break if impeller sticks. Hold the Programme selector button and Start/Pause together for 6 seconds until all indicator LEDs light up, then power off.

Is it safe to clear Hoover error code E02 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Hoover code E02 persists, the physical component causing On Hoover dishwashers featuring H-DISH Maxi Tub architecture, Triple Self-Cleaning micro-filtration wash system, and hOn Wi-Fi connectivity: Magnet pin loose in flowmeter impeller, limescale accumulation inside water jacket labyrinth, or oxidized plug contacts. must be inspected or replaced.

How do I test electrical resistance for Hoover code E02 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Solenoid Valve Coil / Aquastop Pneumatic Valve across Across coil spade terminals (disconnect harness first). Expected nominal reading is 3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop). Tolerance: ±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow..

What safety protocol must be followed before servicing Hoover code E02?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Hoover error code E02 mean on a Dishwasher?

Hoover error code E02 on a Dishwasher indicates: Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out.. Primary cause: On Hoover dishwashers featuring H-DISH Maxi Tub architecture, Triple Self-Cleaning micro-filtration wash system, and hOn Wi-Fi connectivity: Magnet pin loose in flowmeter impeller, limescale accumulation inside water jacket labyrinth, or oxidized plug contacts.. Recommended solution: Inspect left-side plastic air break for scale deposits. Clean electrical contacts on reed switch PCB with contact spray. Replace air break if impeller sticks. Hold the Programme selector button and Start/Pause together for 6 seconds until all indicator LEDs light up, then power off..

What does Hoover error code E02 mean on a Tumble Dryer?

Hoover error code E02 on a Tumble Dryer indicates: Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Process air duct NTC sensor error E02; thermistor signal indicates circuit open, short, or temperature out of operating range.. Primary cause: On Hoover tumble dryers powered by H-DRY Auto Care thermodynamic heat-pump circuit, active conductivity sensor bars, and Eco-Power compressor control: Defective front airflow NTC thermistor bead (~20.0 kΩ at 25°C), disconnected spade terminals, or wire chafing.. Recommended solution: Locate NTC probe at front blower duct. Disconnect wire terminals and measure resistance (~20.0 kΩ at 25°C, ~4.5 kΩ at 60°C). Replace if open. Turn cycle knob to 0, hold Start/Pause and Anti-Crease buttons for 6 seconds until buzzer beeps three times, then switch to Off..

What does Hoover error code E02 mean on a Washing Machine?

Hoover error code E02 on a Washing Machine indicates: Hoover H-WASH 300 / 500 / 700 Eco-Power Inverter Washer: Water inlet fill timeout E02; tub does not reach the minimum operating water level within 210 seconds of valve energization.. Primary cause: On Hoover washing machines with Eco-Power permanent magnet brushless motor, Power Care System premix injection, and hOn AI intelligence: Closed tap, kinked fill hose, clogged inlet valve mesh filter, or open solenoid coil (~3.5–4.5 kΩ).. Recommended solution: Confirm mains water flow rate (>10 L/min). Clean the inlet filter screen. Check dual solenoid valve coil resistances (~3.5–4.5 kΩ). Rotate dial to Off, hold down Start/Pause and Spin Speed keys for 6 seconds until 'rES' appears on the digital readout, then power cycle..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Hoover E02 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Hoover E02 — Dishwasher

[ACTIVE]
Symptom / Description:

Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out.

Root Cause:

On Hoover dishwashers featuring H-DISH Maxi Tub architecture, Triple Self-Cleaning micro-filtration wash system, and hOn Wi-Fi connectivity: Magnet pin loose in flowmeter impeller, limescale accumulation inside water jacket labyrinth, or oxidized plug contacts.

Repair Instructions:

Inspect left-side plastic air break for scale deposits. Clean electrical contacts on reed switch PCB with contact spray. Replace air break if impeller sticks. Hold the Programme selector button and Start/Pause together for 6 seconds until all indicator LEDs light up, then power off.

Hoover E02 — Dryer

Symptom / Description:

Hoover H-DRY 300 / 500 Heat-Pump & Auto Care Tumble Dryer: Process air duct NTC sensor error E02; thermistor signal indicates circuit open, short, or temperature out of operating range.

Root Cause:

On Hoover tumble dryers powered by H-DRY Auto Care thermodynamic heat-pump circuit, active conductivity sensor bars, and Eco-Power compressor control: Defective front airflow NTC thermistor bead (~20.0 kΩ at 25°C), disconnected spade terminals, or wire chafing.

Repair Instructions:

Locate NTC probe at front blower duct. Disconnect wire terminals and measure resistance (~20.0 kΩ at 25°C, ~4.5 kΩ at 60°C). Replace if open. Turn cycle knob to 0, hold Start/Pause and Anti-Crease buttons for 6 seconds until buzzer beeps three times, then switch to Off.

Hoover E02 — Washing Machine

Symptom / Description:

Hoover H-WASH 300 / 500 / 700 Eco-Power Inverter Washer: Water inlet fill timeout E02; tub does not reach the minimum operating water level within 210 seconds of valve energization.

Root Cause:

On Hoover washing machines with Eco-Power permanent magnet brushless motor, Power Care System premix injection, and hOn AI intelligence: Closed tap, kinked fill hose, clogged inlet valve mesh filter, or open solenoid coil (~3.5–4.5 kΩ).

Repair Instructions:

Confirm mains water flow rate (>10 L/min). Clean the inlet filter screen. Check dual solenoid valve coil resistances (~3.5–4.5 kΩ). Rotate dial to Off, hold down Start/Pause and Spin Speed keys for 6 seconds until 'rES' appears on the digital readout, then power cycle.

SEMANTIC KNOWLEDGE GRAPH // HOOVER

Related Hoover Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E03Dishwasher
Drainage System & Drain Pump
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Drain pump evacuation timeout E03; ...
Inspect Protocol
E04Dishwasher
Drainage System & Drain Pump
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Bottom tray anti-flood switch activ...
Inspect Protocol
E05Dishwasher
NTC Temperature Sensor & Thermistor
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Water temperature sensor measuremen...
Inspect Protocol
E06Dishwasher
Electronic Control Board (PCB) & Bus Communications
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Main control board EEPROM verificat...
Inspect Protocol
E07Dishwasher
Drive Motor, Inverter & Tachometer Sensor
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Circulation wash pump motor rotatio...
Inspect Protocol
E08Dishwasher
Heating Element, Thermostat & Safety Fuse
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Flow-through heater circuit open E0...
Inspect Protocol
E1Dishwasher
Water Inlet Valve, Aquastop & Flowmeter
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Water inlet fill failure E1; applia...
Inspect Protocol
E10Dishwasher
Drive Motor, Inverter & Tachometer Sensor
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Water diverter valve timeout E10; m...
Inspect Protocol
E12Dishwasher
Drainage System & Drain Pump
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Software sequence logic fault E12; ...
Inspect Protocol
E14Dishwasher
Water Level Pressure Switch & Air Dome
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Flowmeter signal missing during fil...
Inspect Protocol
E15Dishwasher
Water Level Pressure Switch & Air Dome
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Spray arm rotation / water pressure...
Inspect Protocol
E16Dishwasher
Water Inlet Valve, Aquastop & Flowmeter
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Water softener regeneration valve f...
Inspect Protocol
E17Dishwasher
Water Inlet Valve, Aquastop & Flowmeter
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: High water inlet flow / pressure fa...
Inspect Protocol
E18Dishwasher
Water Level Pressure Switch & Air Dome
Hoover H-DISH 300 / 500 / 700 Maxi Tub Smart Dishwasher: Low water level during circulation ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy