OFFICIAL FAULT CODEF04
Ignis
Ignis // OFFICIAL DIAGNOSTIC BENCH

Ignis F04

DryerDrainage System & Drain Pump
High-efficiency heat pump tumble dryer with ergonomic titanium drum and digital sensor display
Dryer
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code F04:WhirlpoolF04IndesitF04BauknechtF04AristonF04GaggenauF04FAGORF04ScholtèsF04Schaub LorenzF04AmanaF04ArdoF04

Symptom / Description

FAULT

Ignis IGT AirVented & Condenser Tumble Dryer: Condensate evacuation pump failure F04; water collector sump float switch triggers full warning with tank unseated or pump stalled.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Ignis tumble dryers: Sludge and wet lint choking lower pump sump, jammed impeller, broken delivery hose, or open condensate pump coil.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Access lower rear pump housing. Flush condensate collection sump with warm water. Measure pump motor winding resistance (nominal 600–900 Ω or 160–250 Ω). Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Ignis Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpTumble Dryer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Ignis F04

FAQ TREE
What does error code F04 mean on a Ignis appliance?

Ignis error code F04 indicates: Ignis IGT AirVented & Condenser Tumble Dryer: Condensate evacuation pump failure F04; water collector sump float switch triggers full warning with tank unseated or pump stalled..

What is the root cause of Ignis error code F04?

The primary root cause for Ignis code F04 is: On Ignis tumble dryers: Sludge and wet lint choking lower pump sump, jammed impeller, broken delivery hose, or open condensate pump coil..

How do I fix or resolve Ignis error code F04?

To resolve error code F04: Access lower rear pump housing. Flush condensate collection sump with warm water. Measure pump motor winding resistance (nominal 600–900 Ω or 160–250 Ω). Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Is it safe to clear Ignis error code F04 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Ignis code F04 persists, the physical component causing On Ignis tumble dryers: Sludge and wet lint choking lower pump sump, jammed impeller, broken delivery hose, or open condensate pump coil. must be inspected or replaced.

How do I test electrical resistance for Ignis code F04 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Ignis code F04?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // IGNIS

Related Ignis Tumble Dryer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F05Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Electronic moisture conductivity sensor fault ...
Inspect Protocol
F06Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Drum rotation tachometer pulse failure F06; mo...
Inspect Protocol
F07Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Heating element relay contacts welded closed F...
Inspect Protocol
F08Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Heating element open circuit or heat pump comp...
Inspect Protocol
F09Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Control board EEPROM configuration checksum er...
Inspect Protocol
F10Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Motor control module thermal cutoff activation...
Inspect Protocol
F11Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: UI to main control board serial communication ...
Inspect Protocol
F12Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Moisture sensor electrode open circuit F12; co...
Inspect Protocol
F13NTC Temperature Sensor & Thermistor
Ignis IGT AirVented & Condenser Tumble Dryer: Condenser heat exchanger NTC thermistor fault ...
Inspect Protocol
F14Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Heat pump inverter compressor IPM overcurrent ...
Inspect Protocol
F15Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Drum belt tensioner safety switch open F15; mi...
Inspect Protocol
F20NTC Temperature Sensor & Thermistor
Ignis IGT AirVented & Condenser Tumble Dryer: Upper lint filter air flow restriction F20; ai...
Inspect Protocol
F21Drainage System & Drain Pump
Ignis IGT AirVented & Condenser Tumble Dryer: Display to power module serial handshake loss ...
Inspect Protocol
F22Refrigeration Compressor, Defrost Heater & PTC Relay
Ignis IGT AirVented & Condenser Tumble Dryer: Heat pump compressor discharge overtemperature...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy