FAQ TREEWhat does error code F10 mean on a Ignis appliance?
Ignis error code F10 indicates: Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Heating circuit safety relay stuck open F10; DEA700 power module fails to close high-current heater contact..
What is the root cause of Ignis error code F10?
The primary root cause for Ignis code F10 is: On Ignis dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop..
How do I fix or resolve Ignis error code F10?
To resolve error code F10: Inspect DEA700 power module for burned solder pads under heater relay. Measure relay coil continuity (nominal 350–450 Ω). Replace power board if relay damaged. Press and hold Start button for 5 seconds to force drain cycle, wait 60s, then switch off power switch.
Is it safe to clear Ignis error code F10 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Ignis code F10 persists, the physical component causing On Ignis dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop. must be inspected or replaced.
How do I test electrical resistance for Ignis code F10 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Ignis code F10?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.