Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF10
Ignis
Ignis // OFFICIAL DIAGNOSTIC BENCH

Ignis F10

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code F10:MieleF10WhirlpoolF10IndesitF10BauknechtF10AristonF10BrandtF10De DietrichF10LiebherrF10SchulthessF10SauterF10

Symptom / Description

FAULT

Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Heating circuit safety relay stuck open F10; DEA700 power module fails to close high-current heater contact.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Ignis dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Inspect DEA700 power module for burned solder pads under heater relay. Measure relay coil continuity (nominal 350–450 Ω). Replace power board if relay damaged. Press and hold Start button for 5 seconds to force drain cycle, wait 60s, then switch off power switch.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Ignis Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Ignis F10

FAQ TREE
What does error code F10 mean on a Ignis appliance?

Ignis error code F10 indicates: Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Heating circuit safety relay stuck open F10; DEA700 power module fails to close high-current heater contact..

What is the root cause of Ignis error code F10?

The primary root cause for Ignis code F10 is: On Ignis dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop..

How do I fix or resolve Ignis error code F10?

To resolve error code F10: Inspect DEA700 power module for burned solder pads under heater relay. Measure relay coil continuity (nominal 350–450 Ω). Replace power board if relay damaged. Press and hold Start button for 5 seconds to force drain cycle, wait 60s, then switch off power switch.

Is it safe to clear Ignis error code F10 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Ignis code F10 persists, the physical component causing On Ignis dishwashers: Open relay driver transistor on DEA700 PCB, defective relay coil, or broken trace in high-current heating loop. must be inspected or replaced.

How do I test electrical resistance for Ignis code F10 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Ignis code F10?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // IGNIS

Related Ignis Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F11Drainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: BLDC circulation pump inverter drive fau...
Inspect Protocol
F12Drainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Power PCB to user display communication ...
Inspect Protocol
F13Drainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Detergent dispenser actuator triac fault...
Inspect Protocol
F14Water Level Pressure Switch & Air Dome
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Virtual water level sensor calculation d...
Inspect Protocol
F15Drainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Circulation pump motor Hall sensor disco...
Inspect Protocol
F2Drainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: AquaStop base tray leak detected F2; flo...
Inspect Protocol
F3Drainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Wash heating system failure F3; wash wat...
Inspect Protocol
F4Water Level Pressure Switch & Air Dome
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Draining timeout failure F4; water level...
Inspect Protocol
F5Drainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Wash rotor stalled or low spray pressure...
Inspect Protocol
F6Drainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Water inlet tap closed error F6; insuffi...
Inspect Protocol
F7Drainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Flowmeter turbine sensor impulse fault F...
Inspect Protocol
F8Water Level Pressure Switch & Air Dome
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Sump water level inconsistency or divert...
Inspect Protocol
F9Water Level Pressure Switch & Air Dome
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Continuous water fill detected F9; inlet...
Inspect Protocol
FADrainage System & Drain Pump
Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Optical Water Indicator (OWI) turbidity ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy