Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Korting F13_DW
FAQ TREEWhat does error code F13_DW mean on a Korting appliance?
Korting error code F13_DW indicates: Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code F13_DW registered by the microcomputer controller. Dishwasher drain pump motor triac short circuit on power board (drain runs continuously).
What is the root cause of Korting error code F13_DW?
The primary root cause for Korting code F13_DW is: On Körting domestic and cooking appliances engineered on Gorenje-Hisense platforms engineered with Asko/Gorenje hydraulic system, 1800W flow heater (27-31 Ω), BLDC wash pump with tachometer (70-95 Ω), magnetic drain pump (150-190 Ω), and turbidity sensor: short circuit in drain pump winding or rotor stall overcurrent destroyed the semiconductor triac die. Metrological tolerance verification: drain pump winding resistance 150 Ω to 190 Ω; triac main terminals T1-T2 resistance >1.0 MΩ when cold..
How do I fix or resolve Korting error code F13_DW?
To resolve error code F13_DW: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure drain pump coil resistance (150-190 Ω), verify rotor spins freely and test triac terminals on PCB. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance off at power button. Hold Program button continuously for 5 seconds while turning power switch On; wait for LED sequence to confirm reset.
Is it safe to clear Korting error code F13_DW by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Korting code F13_DW persists, the physical component causing On Körting domestic and cooking appliances engineered on Gorenje-Hisense platforms engineered with Asko/Gorenje hydraulic system, 1800W flow heater (27-31 Ω), BLDC wash pump with tachometer (70-95 Ω), magnetic drain pump (150-190 Ω), and turbidity sensor: short circuit in drain pump winding or rotor stall overcurrent destroyed the semiconductor triac die. Metrological tolerance verification: drain pump winding resistance 150 Ω to 190 Ω; triac main terminals T1-T2 resistance >1.0 MΩ when cold. must be inspected or replaced.
How do I test electrical resistance for Korting code F13_DW using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Korting code F13_DW?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?