Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Korting F18_DW
FAQ TREEWhat does error code F18_DW mean on a Korting appliance?
Korting error code F18_DW indicates: Körting KGV / KGI UltraClean Fully Integrated Inverter Dishwasher: Diagnostic fault code F18_DW registered by the microcomputer controller. Dishwasher inline wash water temperature NTC sensor open circuit (>100 kΩ at 25°C).
What is the root cause of Korting error code F18_DW?
The primary root cause for Korting code F18_DW is: On Körting domestic and cooking appliances engineered on Gorenje-Hisense platforms engineered with Asko/Gorenje hydraulic system, 1800W flow heater (27-31 Ω), BLDC wash pump with tachometer (70-95 Ω), magnetic drain pump (150-190 Ω), and turbidity sensor: NTC thermistor bead internal fracture, harness connector dislodged from sump casing, or wire chafed. Metrological tolerance verification: nominal wash NTC resistance 10.0 kΩ at 25°C, 3.8 kΩ at 50°C, 1.2 kΩ at 80°C; smooth resistance slope..
How do I fix or resolve Korting error code F18_DW?
To resolve error code F18_DW: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: disconnect NTC plug under sump base and measure resistance across pins at ambient room temperature (~10 kΩ). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn appliance off at power button. Hold Program button continuously for 5 seconds while turning power switch On; wait for LED sequence to confirm reset.
Is it safe to clear Korting error code F18_DW by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Korting code F18_DW persists, the physical component causing On Körting domestic and cooking appliances engineered on Gorenje-Hisense platforms engineered with Asko/Gorenje hydraulic system, 1800W flow heater (27-31 Ω), BLDC wash pump with tachometer (70-95 Ω), magnetic drain pump (150-190 Ω), and turbidity sensor: NTC thermistor bead internal fracture, harness connector dislodged from sump casing, or wire chafed. Metrological tolerance verification: nominal wash NTC resistance 10.0 kΩ at 25°C, 3.8 kΩ at 50°C, 1.2 kΩ at 80°C; smooth resistance slope. must be inspected or replaced.
How do I test electrical resistance for Korting code F18_DW using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Korting code F18_DW?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



