Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE02
LG
LG // OFFICIAL DIAGNOSTIC BENCH

LG Dishwasher E02

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Other Brands Sharing Code E02:BoschE02SiemensE02SamsungE02ElectroluxE02AEGE02BekoE02HaierE02CandyE02NeffE02V-ZugE02

Symptom / Description

FAULT

LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Waste water draining fault E02; wash sump retains dirty water after 3 minutes of continuous drain pump operation.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On LG dishwashers utilizing QuadWash four-arm multi-directional spray, TrueSteam steam generator, and Inverter DirectDrive motor: Bone or broken glass chip jamming drain pump impeller, blocked sink trap siphon, or open pump motor coil (~160–240 Ω).

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Remove fine micro-filter assembly. Check drain pump impeller cavity under white plastic cover for glass shards. Measure pump resistance (~160–240 Ω). Turn off unit. Press and hold Power and Start simultaneously for 5 seconds until the display chime rings, close door to complete reset.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide LG Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Drain Pump Motor Stator Coils
Nominal Resistance / Test Range
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)
Test Harness Pins
Across pump motor spade terminals (L-N unclipped)
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: LG E02

FAQ TREE
What does error code E02 mean on a LG appliance?

LG error code E02 indicates: LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Waste water draining fault E02; wash sump retains dirty water after 3 minutes of continuous drain pump operation..

What is the root cause of LG error code E02?

The primary root cause for LG code E02 is: On LG dishwashers utilizing QuadWash four-arm multi-directional spray, TrueSteam steam generator, and Inverter DirectDrive motor: Bone or broken glass chip jamming drain pump impeller, blocked sink trap siphon, or open pump motor coil (~160–240 Ω)..

How do I fix or resolve LG error code E02?

To resolve error code E02: Remove fine micro-filter assembly. Check drain pump impeller cavity under white plastic cover for glass shards. Measure pump resistance (~160–240 Ω). Turn off unit. Press and hold Power and Start simultaneously for 5 seconds until the display chime rings, close door to complete reset.

Is it safe to clear LG error code E02 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if LG code E02 persists, the physical component causing On LG dishwashers utilizing QuadWash four-arm multi-directional spray, TrueSteam steam generator, and Inverter DirectDrive motor: Bone or broken glass chip jamming drain pump impeller, blocked sink trap siphon, or open pump motor coil (~160–240 Ω). must be inspected or replaced.

How do I test electrical resistance for LG code E02 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing LG code E02?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does LG error code E02 mean on a Dishwasher?

LG error code E02 on a Dishwasher indicates: LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Waste water draining fault E02; wash sump retains dirty water after 3 minutes of continuous drain pump operation.. Primary cause: On LG dishwashers utilizing QuadWash four-arm multi-directional spray, TrueSteam steam generator, and Inverter DirectDrive motor: Bone or broken glass chip jamming drain pump impeller, blocked sink trap siphon, or open pump motor coil (~160–240 Ω).. Recommended solution: Remove fine micro-filter assembly. Check drain pump impeller cavity under white plastic cover for glass shards. Measure pump resistance (~160–240 Ω). Turn off unit. Press and hold Power and Start simultaneously for 5 seconds until the display chime rings, close door to complete reset..

What does LG error code E02 mean on a Tumble Dryer?

LG error code E02 on a Tumble Dryer indicates: LG Dual Inverter Heat Pump / EcoHybrid Sensor Dry Tumble Dryer: Condensate drain pump timeout or float trip E02; appliance triggers water tank full alarm despite empty collection tank.. Primary cause: On LG dryers featuring Dual Inverter Heat Pump twin-cylinder compressor, auto-cleaning condenser water flush, and Sensor Dry moisture sensing: Blocked condensate sump chamber, stuck polystyrene float switch, kinked discharge hose, or burnt pump coil (~750–950 Ω).. Recommended solution: Access bottom rear/side sump; clear sludge around float switch. Measure pump resistance across terminals (~750–950 Ω at 20°C). Verify float switch clicks (<0.5 Ω closed). Press Power off. Disconnect wall plug for 60 seconds. Hold the Start button for 5 seconds while disconnected to discharge PCB, reconnect mains..

What does LG error code E02 mean on a Hob?

LG error code E02 on a Hob indicates: LG Smart Induction / UltraHeat Dual Zone Induction Cooktop: Induction coil pan detection failure E02; selected zone refuses to energize cookware, displays missing pot symbol, and turns off.. Primary cause: On LG cooktops with UltraHeat dual-ring high-flux induction coils, ThinQ smart monitoring, and safe child lock detection: Open-circuit in copper litz coil winding (<0.3 Ω normal), cracked ferrite concentrator bars underneath coil, or loose coil terminal screws.. Recommended solution: Check coil continuity with ohmmeter: must be <0.3 Ω across coil eyelet leads. Inspect ferrite core bars for physical cracks. Tighten Torx terminal screws to 2.5 Nm. Wipe clean the ceramic glass surface. Switch off cooktop circuit breaker for 60 seconds, restore power, touch and hold Lock key for 4 seconds..

What does LG error code E02 mean on a Oven?

LG error code E02 on a Oven indicates: LG InstaView ProBake Convection / UltraStyle Smart Oven: Pyrolytic door lock mechanism failure E02; door fails to lock during self-clean cycle or remains jammed shut after cooling.. Primary cause: On LG ovens with ProBake Convection rear-wall heating ring, InstaView knock-to-light glass door, and EasyClean enamel: Stripped gear in motorized cam lock actuator (~3.2–4.5 kΩ coil), bent latch hook, or defective lock position microswitches.. Recommended solution: Check lock motor winding resistance (~3.2–4.5 kΩ). Inspect cam gear assembly and test microswitch continuity in locked (<0.5 Ω) and unlocked states. Switch oven dial to Off. Turn off oven breaker on electrical fuse board for 90 seconds. Restore breaker and adjust electronic clock..

What does LG error code E02 mean on a Refrigerator / Freezer?

LG error code E02 on a Refrigerator / Freezer indicates: LG InstaView Door-in-Door / Linear Compressor Total No-Frost Refrigerator: Freezer compartment temperature sensor defect E02; freezer warm alert triggers and compressor runs continuously without stopping.. Primary cause: On LG refrigeration units with Inverter Linear Compressor with direct piston mechanism, DoorCooling+ air vents, and LinearCooling ±0.5°C control: Open or shorted freezer cavity NTC thermistor (~5–10 kΩ at 25°C, ~30–35 kΩ at -18°C), or sensor cable grounded to chassis.. Recommended solution: Test sensor resistance across board terminals: expected ~30–35 kΩ at -18°C (~5–10 kΩ at 25°C). Replace defective freezer sensor module with OEM spare. Open freezer and fresh food doors. Press and hold Express Freeze and Wi-Fi buttons together for 6 seconds until chime confirms reset..

What does LG error code E02 mean on a Washing Machine?

LG error code E02 on a Washing Machine indicates: LG AI DD / TurboWash 360 / Centum System Direct Drive Washer: Water intake timeout E02; drum water level does not reach target threshold within 5 minutes of fill valve activation.. Primary cause: On LG washing machines utilizing AI DD artificial intelligence direct drive, 6 Motion DD kinematics, and TurboWash 360 multi-nozzle injection: Low water supply pressure (<0.8 bar), blocked inlet filter screen, or open dual solenoid valve coil (~3.6–4.8 kΩ).. Recommended solution: Check water tap flow rate (>10 L/min). Clean the inlet hose filter mesh. Measure resistance across solenoid valve coils (~3.6–4.8 kΩ). Press Power to turn off. Unplug from mains for 5 seconds. Hold Start/Pause for 5 seconds with unit unplugged to discharge capacitors, then plug in..

Community Verification

COMMUNITY

Did this solution resolve the issue?

LG E02 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

LG E02 — Dishwasher

[ACTIVE]
Symptom / Description:

LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Waste water draining fault E02; wash sump retains dirty water after 3 minutes of continuous drain pump operation.

Root Cause:

On LG dishwashers utilizing QuadWash four-arm multi-directional spray, TrueSteam steam generator, and Inverter DirectDrive motor: Bone or broken glass chip jamming drain pump impeller, blocked sink trap siphon, or open pump motor coil (~160–240 Ω).

Repair Instructions:

Remove fine micro-filter assembly. Check drain pump impeller cavity under white plastic cover for glass shards. Measure pump resistance (~160–240 Ω). Turn off unit. Press and hold Power and Start simultaneously for 5 seconds until the display chime rings, close door to complete reset.

LG E02 — Dryer

Symptom / Description:

LG Dual Inverter Heat Pump / EcoHybrid Sensor Dry Tumble Dryer: Condensate drain pump timeout or float trip E02; appliance triggers water tank full alarm despite empty collection tank.

Root Cause:

On LG dryers featuring Dual Inverter Heat Pump twin-cylinder compressor, auto-cleaning condenser water flush, and Sensor Dry moisture sensing: Blocked condensate sump chamber, stuck polystyrene float switch, kinked discharge hose, or burnt pump coil (~750–950 Ω).

Repair Instructions:

Access bottom rear/side sump; clear sludge around float switch. Measure pump resistance across terminals (~750–950 Ω at 20°C). Verify float switch clicks (<0.5 Ω closed). Press Power off. Disconnect wall plug for 60 seconds. Hold the Start button for 5 seconds while disconnected to discharge PCB, reconnect mains.

LG E02 — Hob

Symptom / Description:

LG Smart Induction / UltraHeat Dual Zone Induction Cooktop: Induction coil pan detection failure E02; selected zone refuses to energize cookware, displays missing pot symbol, and turns off.

Root Cause:

On LG cooktops with UltraHeat dual-ring high-flux induction coils, ThinQ smart monitoring, and safe child lock detection: Open-circuit in copper litz coil winding (<0.3 Ω normal), cracked ferrite concentrator bars underneath coil, or loose coil terminal screws.

Repair Instructions:

Check coil continuity with ohmmeter: must be <0.3 Ω across coil eyelet leads. Inspect ferrite core bars for physical cracks. Tighten Torx terminal screws to 2.5 Nm. Wipe clean the ceramic glass surface. Switch off cooktop circuit breaker for 60 seconds, restore power, touch and hold Lock key for 4 seconds.

LG E02 — Oven

Symptom / Description:

LG InstaView ProBake Convection / UltraStyle Smart Oven: Pyrolytic door lock mechanism failure E02; door fails to lock during self-clean cycle or remains jammed shut after cooling.

Root Cause:

On LG ovens with ProBake Convection rear-wall heating ring, InstaView knock-to-light glass door, and EasyClean enamel: Stripped gear in motorized cam lock actuator (~3.2–4.5 kΩ coil), bent latch hook, or defective lock position microswitches.

Repair Instructions:

Check lock motor winding resistance (~3.2–4.5 kΩ). Inspect cam gear assembly and test microswitch continuity in locked (<0.5 Ω) and unlocked states. Switch oven dial to Off. Turn off oven breaker on electrical fuse board for 90 seconds. Restore breaker and adjust electronic clock.

LG E02 — Refrigerator / Freezer

Symptom / Description:

LG InstaView Door-in-Door / Linear Compressor Total No-Frost Refrigerator: Freezer compartment temperature sensor defect E02; freezer warm alert triggers and compressor runs continuously without stopping.

Root Cause:

On LG refrigeration units with Inverter Linear Compressor with direct piston mechanism, DoorCooling+ air vents, and LinearCooling ±0.5°C control: Open or shorted freezer cavity NTC thermistor (~5–10 kΩ at 25°C, ~30–35 kΩ at -18°C), or sensor cable grounded to chassis.

Repair Instructions:

Test sensor resistance across board terminals: expected ~30–35 kΩ at -18°C (~5–10 kΩ at 25°C). Replace defective freezer sensor module with OEM spare. Open freezer and fresh food doors. Press and hold Express Freeze and Wi-Fi buttons together for 6 seconds until chime confirms reset.

LG E02 — Washing Machine

Symptom / Description:

LG AI DD / TurboWash 360 / Centum System Direct Drive Washer: Water intake timeout E02; drum water level does not reach target threshold within 5 minutes of fill valve activation.

Root Cause:

On LG washing machines utilizing AI DD artificial intelligence direct drive, 6 Motion DD kinematics, and TurboWash 360 multi-nozzle injection: Low water supply pressure (<0.8 bar), blocked inlet filter screen, or open dual solenoid valve coil (~3.6–4.8 kΩ).

Repair Instructions:

Check water tap flow rate (>10 L/min). Clean the inlet hose filter mesh. Measure resistance across solenoid valve coils (~3.6–4.8 kΩ). Press Power to turn off. Unplug from mains for 5 seconds. Hold Start/Pause for 5 seconds with unit unplugged to discharge capacitors, then plug in.

SEMANTIC KNOWLEDGE GRAPH // LG

Related LG Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E03Dishwasher
NTC Temperature Sensor & Thermistor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Water heating failure E03; wash b...
Inspect Protocol
E04Dishwasher
Drainage System & Drain Pump
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Base pan leak detection E04; poly...
Inspect Protocol
E05Dishwasher
NTC Temperature Sensor & Thermistor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Temperature sensor communication ...
Inspect Protocol
E06Dishwasher
Drive Motor, Inverter & Tachometer Sensor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Circulation pump motor stall E06;...
Inspect Protocol
E07Dishwasher
Drive Motor, Inverter & Tachometer Sensor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Spray diverter positioning error ...
Inspect Protocol
E08Dishwasher
Water Inlet Valve, Aquastop & Flowmeter
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Water softener circuit fault E08;...
Inspect Protocol
E09Dishwasher
Drive Motor, Inverter & Tachometer Sensor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: AquaSensor turbidity calibration ...
Inspect Protocol
E10Dishwasher
Drive Motor, Inverter & Tachometer Sensor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Appliance configuration error E10...
Inspect Protocol
E11Dishwasher
Drive Motor, Inverter & Tachometer Sensor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Communication bus loss E11; door ...
Inspect Protocol
E12Dishwasher
Water Level Pressure Switch & Air Dome
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Water level sensor mismatch E12; ...
Inspect Protocol
E13Dishwasher
Drive Motor, Inverter & Tachometer Sensor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Detergent dispenser actuator erro...
Inspect Protocol
E14Dishwasher
Heating Element, Thermostat & Safety Fuse
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Active drying system fault E14; z...
Inspect Protocol
E15Dishwasher
Drive Motor, Inverter & Tachometer Sensor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: Power module DC voltage failure E...
Inspect Protocol
F01Dishwasher
Drive Motor, Inverter & Tachometer Sensor
LG QuadWash / TrueSteam / Inverter DirectDrive Dishwasher: BLDC wash pump inverter imbalance...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy