Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: LG ICE MAKER SENSOR ERROR
FAQ TREEWhat does error code ICE MAKER SENSOR ERROR mean on a LG appliance?
LG error code ICE MAKER SENSOR ERROR indicates: Ice maker Sensor Error is displayed.. Diagnostic error code Ice maker Sensor Error reported on LG Refrigerator..
What is the root cause of LG error code ICE MAKER SENSOR ERROR?
The primary root cause for LG code ICE MAKER SENSOR ERROR is: On LG Refrigerator: Loose connection (CON13), defective I/Maker (ice maker) sensor, defective I/Maker unit, defective main PCB..
How do I fix or resolve LG error code ICE MAKER SENSOR ERROR?
To resolve error code ICE MAKER SENSOR ERROR: On LG Refrigerator: Reconnect CON13. If the same situation appears, disconnect CON13 and measure resistance (Pin1 & Pin2 of CON13, GY to GY, 6 ~ 150 Result). If abnormal, replace I/Maker. If the same situation appears again, replace the main PCB.
Is it safe to clear LG error code ICE MAKER SENSOR ERROR by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if LG code ICE MAKER SENSOR ERROR persists, the physical component causing On LG Refrigerator: Loose connection (CON13), defective I/Maker (ice maker) sensor, defective I/Maker unit, defective main PCB. must be inspected or replaced.
How do I test electrical resistance for LG code ICE MAKER SENSOR ERROR using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test PCB Power Supply Rails & DC Bus Filter Capacitors across Across SMPS output electrolytic capacitors on low-voltage side (test bench verification). Expected nominal reading is Low-voltage rails: +5.0V DC (Logic), +12.0V DC (Relays), +3.3V DC (MCU). Relay coils: 200Ω–450Ω.. Tolerance: DC rail ripple must remain <50mV. Direct continuity (0Ω) across DC bus rails indicates dead short..
What safety protocol must be followed before servicing LG code ICE MAKER SENSOR ERROR?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?