Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Maytag F25
FAQ TREEWhat does error code F25 mean on a Maytag appliance?
Maytag error code F25 indicates: Maytag MEC Speed Heat Radiant & Induction Cooktop: Cooking zone element temperature sensor fault F25; designated cooking zone is shut down to prevent ceramic glass overheating..
What is the root cause of Maytag error code F25?
The primary root cause for Maytag code F25 is: On Maytag cooktops (Maytag Commercial Technology heavy-duty direct drive chassis and industrial-grade relays): NTC thermistor bead in center of induction coil or radiant element open circuit (>500 kΩ) or shorted to coil chassis..
How do I fix or resolve Maytag error code F25?
To resolve error code F25: Unplug cooktop. Disconnect sensor connector from power board. Measure coil NTC resistance: nominal 100 kΩ or 10 kΩ at 25°C (77°F). Replace coil sensor if open/short. Switch off double-pole 240V supply breaker for 3 minutes. Clean ceramic surface and restore power to recalibrate touch controls.
Is it safe to clear Maytag error code F25 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Maytag code F25 persists, the physical component causing On Maytag cooktops (Maytag Commercial Technology heavy-duty direct drive chassis and industrial-grade relays): NTC thermistor bead in center of induction coil or radiant element open circuit (>500 kΩ) or shorted to coil chassis. must be inspected or replaced.
How do I test electrical resistance for Maytag code F25 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Maytag code F25?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?