OFFICIAL FAULT CODEF25
Ignis
Ignis // OFFICIAL DIAGNOSTIC BENCH

Ignis F25

HobNTC Temperature Sensor & Thermistor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Hob
Other Brands Sharing Code F25:BoschF25MieleF25SiemensF25WhirlpoolF25IndesitF25BauknechtF25NeffF25AristonF25GaggenauF25AmanaF25

Symptom / Description

FAULT

Ignis Platino Induction & Ceramic Cooktop: Rear induction zone center temperature sensor disconnect F25; glass ceramic sensor spring probe circuit open.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Ignis cooktops: Broken copper wire at coil center spring eyelet, oxidized plug on generator board, or cracked ceramic thermistor chip.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Unclip glass top and access rear induction coil. Measure center spring NTC probe resistance (nominal ~100 kΩ at 25°C). Replace central coil sensor. Power down at breaker switch for 60 seconds, wipe surface dry with microfiber cloth, then restart.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Ignis Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorHob / Cooktop
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Ignis F25

FAQ TREE
What does error code F25 mean on a Ignis appliance?

Ignis error code F25 indicates: Ignis Platino Induction & Ceramic Cooktop: Rear induction zone center temperature sensor disconnect F25; glass ceramic sensor spring probe circuit open..

What is the root cause of Ignis error code F25?

The primary root cause for Ignis code F25 is: On Ignis cooktops: Broken copper wire at coil center spring eyelet, oxidized plug on generator board, or cracked ceramic thermistor chip..

How do I fix or resolve Ignis error code F25?

To resolve error code F25: Unclip glass top and access rear induction coil. Measure center spring NTC probe resistance (nominal ~100 kΩ at 25°C). Replace central coil sensor. Power down at breaker switch for 60 seconds, wipe surface dry with microfiber cloth, then restart.

Is it safe to clear Ignis error code F25 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Ignis code F25 persists, the physical component causing On Ignis cooktops: Broken copper wire at coil center spring eyelet, oxidized plug on generator board, or cracked ceramic thermistor chip. must be inspected or replaced.

How do I test electrical resistance for Ignis code F25 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Ignis code F25?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // IGNIS

Related Ignis Hob / Cooktop Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F36NTC Temperature Sensor & Thermistor
Ignis Platino Induction & Ceramic Cooktop: Front left induction coil NTC sensor calibration ...
Inspect Protocol
F37Heating Element, Thermostat & Safety Fuse
Ignis Platino Induction & Ceramic Cooktop: Power board mains input voltage out of tolerance ...
Inspect Protocol
F40Drive Motor, Inverter & Tachometer Sensor
Ignis Platino Induction & Ceramic Cooktop: Left induction generator module bus communication...
Inspect Protocol
F42General System & Mechanical Integration
Ignis Platino Induction & Ceramic Cooktop: Incorrect mains line supply connection F42; 400V ...
Inspect Protocol
F47Heating Element, Thermostat & Safety Fuse
Ignis Platino Induction & Ceramic Cooktop: LIN bus communication lost between touch UI and p...
Inspect Protocol
C81NTC Temperature Sensor & Thermistor
Ignis Platino Induction & Ceramic Cooktop: Touch control panel thermal warning C81; temperat...
Inspect Protocol
C82Electronic Control Board (PCB) & Bus Communications
Ignis Platino Induction & Ceramic Cooktop: Electronic power module thermal overload C82; hea...
Inspect Protocol
C83Drive Motor, Inverter & Tachometer Sensor
Ignis Platino Induction & Ceramic Cooktop: Mains supply undervoltage trip C83; inverter filt...
Inspect Protocol
C84General System & Mechanical Integration
Ignis Platino Induction & Ceramic Cooktop: Mains overvoltage detected across filter stage C8...
Inspect Protocol
C85General System & Mechanical Integration
Ignis Platino Induction & Ceramic Cooktop: Incompatible cookware detected by induction coil ...
Inspect Protocol
F01Electronic Control Board (PCB) & Bus Communications
Ignis Platino Induction & Ceramic Cooktop: Induction power module bus disconnection F01; tou...
Inspect Protocol
F02Water Level Pressure Switch & Air Dome
Ignis Platino Induction & Ceramic Cooktop: Touch control surface overheating or liquid spill...
Inspect Protocol
F03NTC Temperature Sensor & Thermistor
Ignis Platino Induction & Ceramic Cooktop: Induction power module heatsink NTC temperature s...
Inspect Protocol
F04Drive Motor, Inverter & Tachometer Sensor
Ignis Platino Induction & Ceramic Cooktop: Mains supply undervoltage or missing phase error ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy