FAQ TREEWhat does error code F113 mean on a Miele appliance?
Miele error code F113 indicates: The temperature of a second additional compartment is poorly regulated, with fault F113 displayed..
What is the root cause of Miele error code F113?
The primary root cause for Miele code F113 is: The temperature sensor in the second specialized compartment of the device is defective..
How do I fix or resolve Miele error code F113?
To resolve error code F113: Unplug the appliance from the mains. Locate the second compartment temperature sensor. Perform a resistance test using a multimeter. If the probe is confirmed to be faulty, it must be changed.
Is it safe to clear Miele error code F113 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Miele code F113 persists, the physical component causing The temperature sensor in the second specialized compartment of the device is defective. must be inspected or replaced.
How do I test electrical resistance for Miele code F113 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Miele code F113?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.