Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Rosieres U
FAQ TREEWhat does error code U mean on a Rosieres appliance?
Rosieres error code U indicates: Rosières RVI / RPI Piano de Cuisson & Induction Cooktop: Mains supply undervoltage / phase missing alert U; cooktop detects open circuit on secondary phase or voltage under 170V AC..
What is the root cause of Rosieres error code U?
The primary root cause for Rosieres code U is: On Rosières cooktops utilizing Piano de Cuisson induction generator, heavy-duty electromagnetic coils, and high-temperature thermal safety module: Missing copper bridging link between terminals 1 and 2 on single-phase 230V installations, or tripped split breaker..
How do I fix or resolve Rosieres error code U?
To resolve error code U: Turn off breaker. Check junction box on hob underside. Ensure copper bridge jumper is securely tightened across terminals 1 and 2 for 230V single phase. Clear pan from hob surface, turn off electrical isolator for 60 seconds, turn back on and press Key Lock sensor for 5 seconds.
Is it safe to clear Rosieres error code U by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code U persists, the physical component causing On Rosières cooktops utilizing Piano de Cuisson induction generator, heavy-duty electromagnetic coils, and high-temperature thermal safety module: Missing copper bridging link between terminals 1 and 2 on single-phase 230V installations, or tripped split breaker. must be inspected or replaced.
How do I test electrical resistance for Rosieres code U using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test PCB Power Supply Rails & DC Bus Filter Capacitors across Across SMPS output electrolytic capacitors on low-voltage side (test bench verification). Expected nominal reading is Low-voltage rails: +5.0V DC (Logic), +12.0V DC (Relays), +3.3V DC (MCU). Relay coils: 200Ω–450Ω.. Tolerance: DC rail ripple must remain <50mV. Direct continuity (0Ω) across DC bus rails indicates dead short..
What safety protocol must be followed before servicing Rosieres code U?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?