Samsung F01 — Dishwasher
[ACTIVE]Samsung WaterWall / StormWash / Bespoke Linear Wash Dishwasher: BLDC wash pump inverter imbalance F01; microcontroller detects asymmetric phase currents across three-phase stator coils.
On Samsung dishwashers utilizing WaterWall sweeping linear spray bar, StormWash rotating nozzle cluster, and auto-release door opening: Internal winding turn short in circulation pump stator, corroded connector pins, or blown output MOSFET on inverter.
Disconnect circulation pump plug. Measure phase resistances across U-V, V-W, U-W with precision ohmmeter (all values must match within ±0.3 Ω, ~48–92 Ω). Press and hold the Start/Reset button for 3 seconds until '0:01' or 'CL' appears, wait for drain cycle completion, then cycle power off.