Scholtès F14 — Oven
[ACTIVE]Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F14 registered by the microcomputer controller. Steam generator fill solenoid valve timeout / no water detected
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: boiler water feed pump failed or water line airlocked Metrological tolerance verification: feed pump coil resistance ~120 Ω..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure water injection pump coil resistance and inspect water tank filter. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.