Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF14
Scholtès
Scholtès // OFFICIAL DIAGNOSTIC BENCH

Scholtès Oven F14

OvenWater Inlet Valve, Aquastop & Flowmeter
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Select Appliance Type
0ms Instant Telemetry Switch
Whirlpool / Indesit Group: Equivalent Code Across OEM Group Brands
Whirlpool / Indesit Global Electronic Architecture
WhirlpoolF14IndesitF14AristonF14HotpointF14BauknechtF14IgnisF14
Other Brands Sharing Code F14:MieleF14V-ZugF14LiebherrF14Schaub LorenzF14BaumaticF14BompaniF14

Symptom / Description

FAULT

Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F14 registered by the microcomputer controller. Steam generator fill solenoid valve timeout / no water detected

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: boiler water feed pump failed or water line airlocked Metrological tolerance verification: feed pump coil resistance ~120 Ω..

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure water injection pump coil resistance and inspect water tank filter. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Scholtès Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Water Inlet, Aquastop & Flowmeter Loop

Inlet Solenoid Valve Y1, Reed Turbine Flowmeter & Aquastop Float S2

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III3.84 kΩVΩCOMINLET VALVE Y1SOLENOID Y1: 4.0 kΩFLOWMETER B1 (REED)AQUASTOP SWITCH S2: 0.0Ω
Target Component
Solenoid Valve Coil / Aquastop Pneumatic Valve
Nominal Resistance / Test Range
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)
Test Harness Pins
Across coil spade terminals (disconnect harness first)
Diagnostic Verification Rule
OL on solenoid indicates open coil. Closed contact on float switch S2 indicates base pan leak.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLWater Inlet Valve, Aquastop & FlowmeterOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Solenoid Valve Coil / Aquastop Pneumatic Valve
Test Pins & Connections
PROBE (+)
PROBE (-)
Across coil spade terminals (disconnect harness first)
Tolerance & Diagnostic Criteria±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical power before touching solenoid valve coils or Aquastop connectors.
  • !Firmly shut off the domc water supply tap before unscrewing the inlet hose fitting.
  • !Check safety base drip tray for accumulated water triggering the anti-flood polystyrene float switch.
3. Preliminary Mechanical & Visual Checks
  • Remove and clean sediment and sand particles from the 3/4" inlet hose metal mesh filter.
  • Verify domestic dynamic water pressure is between 1.0 and 10.0 bar (0.1 to 1.0 MPa).
  • Inspect outer Aquastop hose jacket for expansion, pinch damage, or internal leak reservoir triggering.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Scholtès F14

FAQ TREE
What does error code F14 mean on a Scholtès appliance?

Scholtès error code F14 indicates: Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F14 registered by the microcomputer controller. Steam generator fill solenoid valve timeout / no water detected.

What is the root cause of Scholtès error code F14?

The primary root cause for Scholtès code F14 is: On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: boiler water feed pump failed or water line airlocked Metrological tolerance verification: feed pump coil resistance ~120 Ω...

How do I fix or resolve Scholtès error code F14?

To resolve error code F14: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure water injection pump coil resistance and inspect water tank filter. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.

Is it safe to clear Scholtès error code F14 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Scholtès code F14 persists, the physical component causing On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: boiler water feed pump failed or water line airlocked Metrological tolerance verification: feed pump coil resistance ~120 Ω.. must be inspected or replaced.

How do I test electrical resistance for Scholtès code F14 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Solenoid Valve Coil / Aquastop Pneumatic Valve across Across coil spade terminals (disconnect harness first). Expected nominal reading is 3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop). Tolerance: ±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow..

What safety protocol must be followed before servicing Scholtès code F14?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Scholtès error code F14 mean on a Oven?

Scholtès error code F14 on a Oven indicates: Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F14 registered by the microcomputer controller. Steam generator fill solenoid valve timeout / no water detected. Primary cause: On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: boiler water feed pump failed or water line airlocked Metrological tolerance verification: feed pump coil resistance ~120 Ω... Recommended solution: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure water injection pump coil resistance and inspect water tank filter. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes..

What does Scholtès error code F14 mean on a Washing Machine?

Scholtès error code F14 on a Washing Machine indicates: Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F14 registered by the microcomputer controller. Dryer heating element open circuit (Washer-Dryer). Primary cause: On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: drying heating element wire open Metrological tolerance verification: nominal 32.0 Ω to 38.0 Ω (1400W / 230V)... Recommended solution: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across dryer heating element terminals. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code..

What does Scholtès error code F14 mean on a Tumble Dryer?

Scholtès error code F14 on a Tumble Dryer indicates: Scholtès Heat Pump Sensor Dry Tumble Dryer: Heat pump inverter compressor IPM overcurrent protection F14; drive module detects compressor phase over-amperage or lockup.. Primary cause: On Scholtès heat pump tumble dryers: Refrigerant circuit pressure unbalance, shorted BLDC compressor stator winding, or failed inverter power module.. Recommended solution: Allow 20 minutes for refrigerant pressure equalization. Measure compressor terminal resistances across all 3 phases (symmetrical ~8–14 Ω). Replace inverter or compressor. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Scholtès F14 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Scholtès F14 — Oven

[ACTIVE]
Symptom / Description:

Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F14 registered by the microcomputer controller. Steam generator fill solenoid valve timeout / no water detected

Root Cause:

On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: boiler water feed pump failed or water line airlocked Metrological tolerance verification: feed pump coil resistance ~120 Ω..

Repair Instructions:

Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure water injection pump coil resistance and inspect water tank filter. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.

Scholtès F14 — Washing Machine

Symptom / Description:

Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F14 registered by the microcomputer controller. Dryer heating element open circuit (Washer-Dryer)

Root Cause:

On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: drying heating element wire open Metrological tolerance verification: nominal 32.0 Ω to 38.0 Ω (1400W / 230V)..

Repair Instructions:

Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across dryer heating element terminals. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.

Scholtès F14 — Dryer

Symptom / Description:

Scholtès Heat Pump Sensor Dry Tumble Dryer: Heat pump inverter compressor IPM overcurrent protection F14; drive module detects compressor phase over-amperage or lockup.

Root Cause:

On Scholtès heat pump tumble dryers: Refrigerant circuit pressure unbalance, shorted BLDC compressor stator winding, or failed inverter power module.

Repair Instructions:

Allow 20 minutes for refrigerant pressure equalization. Measure compressor terminal resistances across all 3 phases (symmetrical ~8–14 Ω). Replace inverter or compressor. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.

SEMANTIC KNOWLEDGE GRAPH // SCHOLTÈS

Related Scholtès Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F15Oven
Drainage System & Drain Pump
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F15 re...
Inspect Protocol
F16Oven
NTC Temperature Sensor & Thermistor
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F16 re...
Inspect Protocol
F17Oven
Drive Motor, Inverter & Tachometer Sensor
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F17 re...
Inspect Protocol
F18_OVOven
Drive Motor, Inverter & Tachometer Sensor
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F18_OV...
Inspect Protocol
F19Oven
Heating Element, Thermostat & Safety Fuse
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F19 re...
Inspect Protocol
F20Oven
Heating Element, Thermostat & Safety Fuse
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F20 re...
Inspect Protocol
STOPOven
NTC Temperature Sensor & Thermistor
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code STOP r...
Inspect Protocol
F1 E0Oven
Electronic Control Board (PCB) & Bus Communications
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Electronic range control (ERC) EEPROM c...
Inspect Protocol
F1 E1Oven
Heating Element, Thermostat & Safety Fuse
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Relay board microprocessor communicatio...
Inspect Protocol
F2 E0Oven
Electronic Control Board (PCB) & Bus Communications
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Shorted keypad touch pad switch F2 E0; ...
Inspect Protocol
F2 E1Oven
Electronic Control Board (PCB) & Bus Communications
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Keypad ribbon cable disconnected F2 E1;...
Inspect Protocol
F3 E0Oven
NTC Temperature Sensor & Thermistor
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Oven cavity temperature sensor (RTD) op...
Inspect Protocol
Er01Oven
Drive Motor, Inverter & Tachometer Sensor
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code Er01 r...
Inspect Protocol
Er02Oven
Drive Motor, Inverter & Tachometer Sensor
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code Er02 r...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy