Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE104
Siemens
Siemens // OFFICIAL DIAGNOSTIC BENCH

Siemens E104

OvenNTC Temperature Sensor & Thermistor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Other Brands Sharing Code E104:BoschE104NeffE104GaggenauE104

Symptom / Description

FAULT

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Multi-point core meat temperature probe fault E104; probe socket shorted or temperature sensing channels inconsistent.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Siemens ovens: Grease/moisture ingress into side cavity jack socket, damaged multi-core probe cable, or bent jack plug contacts.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Unplug core probe. Inspect internal cavity jack socket and clean with electrical solvent. Measure resistance between jack plug rings (~10 kΩ at 25°C). Touch On/Off sensor, isolate circuit breaker for 60 seconds, re-engage and touch Key lock symbol for 3 seconds.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Siemens Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Siemens E104

FAQ TREE
What does error code E104 mean on a Siemens appliance?

Siemens error code E104 indicates: Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Multi-point core meat temperature probe fault E104; probe socket shorted or temperature sensing channels inconsistent..

What is the root cause of Siemens error code E104?

The primary root cause for Siemens code E104 is: On Siemens ovens: Grease/moisture ingress into side cavity jack socket, damaged multi-core probe cable, or bent jack plug contacts..

How do I fix or resolve Siemens error code E104?

To resolve error code E104: Unplug core probe. Inspect internal cavity jack socket and clean with electrical solvent. Measure resistance between jack plug rings (~10 kΩ at 25°C). Touch On/Off sensor, isolate circuit breaker for 60 seconds, re-engage and touch Key lock symbol for 3 seconds.

Is it safe to clear Siemens error code E104 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Siemens code E104 persists, the physical component causing On Siemens ovens: Grease/moisture ingress into side cavity jack socket, damaged multi-core probe cable, or bent jack plug contacts. must be inspected or replaced.

How do I test electrical resistance for Siemens code E104 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Siemens code E104?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // SIEMENS

Related Siemens Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E106Drive Motor, Inverter & Tachometer Sensor
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Tangential ...
Inspect Protocol
E115NTC Temperature Sensor & Thermistor
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity high...
Inspect Protocol
E305Electronic Control Board (PCB) & Bus Communications
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Internal se...
Inspect Protocol
E310Drive Motor, Inverter & Tachometer Sensor
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic d...
Inspect Protocol
E395Drive Motor, Inverter & Tachometer Sensor
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic d...
Inspect Protocol
E396Door Lock Mechanism & Safety Interlock
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic d...
Inspect Protocol
E5116Heating Element, Thermostat & Safety Fuse
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-micro...
Inspect Protocol
E5121Drive Motor, Inverter & Tachometer Sensor
Pyrolytic cleaning aborted / Door fault
Inspect Protocol
E845Water Level Pressure Switch & Air Dome
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-steam...
Inspect Protocol
Er1NTC Temperature Sensor & Thermistor
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity PT10...
Inspect Protocol
Er2General System & Mechanical Integration
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Mains conne...
Inspect Protocol
Er4Door Lock Mechanism & Safety Interlock
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Electronic ...
Inspect Protocol
Er6Drive Motor, Inverter & Tachometer Sensor
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic d...
Inspect Protocol
Er8Drive Motor, Inverter & Tachometer Sensor
Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-micro...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy