Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE104
Bosch
Bosch // OFFICIAL DIAGNOSTIC BENCH

Bosch E104

OvenNTC Temperature Sensor & Thermistor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven

Symptom / Description

FAULT

Short circuit oven – temperature sensor (PT 500)

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

1. Bad connection (corrosive/chipped contact). 2. Broken cable. 3. PT500 (NTC) is different. 4. Fault on the control module

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1PT500: Check connectors and cables. Replace the PT500 cavity. Replaces the PT500. Replace the control module
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bosch Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bosch E104

FAQ TREE
What does error code E104 mean on a Bosch appliance?

Bosch error code E104 indicates: Short circuit oven – temperature sensor (PT 500).

What is the root cause of Bosch error code E104?

The primary root cause for Bosch code E104 is: 1. Bad connection (corrosive/chipped contact). 2. Broken cable. 3. PT500 (NTC) is different. 4. Fault on the control module.

How do I fix or resolve Bosch error code E104?

To resolve error code E104: PT500: Check connectors and cables. Replace the PT500 cavity. Replaces the PT500. Replace the control module

Is it safe to clear Bosch error code E104 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E104 persists, the physical component causing 1. Bad connection (corrosive/chipped contact). 2. Broken cable. 3. PT500 (NTC) is different. 4. Fault on the control module must be inspected or replaced.

How do I test electrical resistance for Bosch code E104 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Bosch code E104?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // BOSCH

Related Bosch Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E106Drive Motor, Inverter & Tachometer Sensor
Pyrolytic self-cleaning door locking mechanism failure; door cannot lock or unlock.
Inspect Protocol
E107Drive Motor, Inverter & Tachometer Sensor
The door does not open because it is locked. The display shows "Oven not unlocked".
Inspect Protocol
E115General System & Mechanical Integration
Appliance main switch relay turns off and the appliance switches to a functionally safe state.
Inspect Protocol
E136NTC Temperature Sensor & Thermistor
Inverter temperature (IGBT) is three times higher
Inspect Protocol
E137Heating Element, Thermostat & Safety Fuse
Microwave inverter IGBT power transistor over-temperature safety shutdown.
Inspect Protocol
E138Drive Motor, Inverter & Tachometer Sensor
Inverter “Connector Error” H 95
Inspect Protocol
E139Drive Motor, Inverter & Tachometer Sensor
Invert “Fault in Control IC” H 96-1
Inspect Protocol
E140Drive Motor, Inverter & Tachometer Sensor
Invert “Fault in Control IC” H 96-2
Inspect Protocol
E141Drive Motor, Inverter & Tachometer Sensor
Inverter “Control Error” H 97
Inspect Protocol
E142Drive Motor, Inverter & Tachometer Sensor
Bosch E142: Motor drive or inverter rotation anomaly in Oven / Microwave; drum/motor fails t...
Inspect Protocol
E143Drive Motor, Inverter & Tachometer Sensor
Pulses from the inverter H 99
Inspect Protocol
E144Electronic Control Board (PCB) & Bus Communications
Plausibility check (Double ovens --> Oven cavity 1)
Inspect Protocol
E244Electronic Control Board (PCB) & Bus Communications
Plausibility check (Double ovens --> Oven cavity 2)
Inspect Protocol
E300Electronic Control Board (PCB) & Bus Communications
Unsatisfactory baking result or functions of the buttons do not correspond, appliance is in ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy