OFFICIAL FAULT CODEE107
Bosch
Bosch // OFFICIAL DIAGNOSTIC BENCH

Bosch E107

OvenDrive Motor, Inverter & Tachometer Sensor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven

Symptom / Description

FAULT

The door does not open because it is locked. The display shows "Oven not unlocked".

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

A door lock produced up to FD9103 had geometry that caused the hook to rub against the door insert, blocking movement. This prevented correct actuation of the microswitches, leading the electronics to detect an incorrect switching position.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Check if there is blocking of the lock and support of the lock; Motor lock: connection and cable controller; Engine changer lock; Check wiring according to diagram, correct; Correct position of micro-switches on the support frame; Change micro-switch; Change control module
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bosch Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrive Motor, Inverter & Tachometer SensorOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Test Pins & Connections
PROBE (+)
PROBE (-)
Across phase pins U-V, V-W, U-W on motor harness; across tacho pins
Tolerance & Diagnostic CriteriaBLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho.
1. Pre-Intervention Electrical Safety Protocols
  • !High-Voltage Safety Protocol & DC Bus: Wait at least 5 minutes after power cutoff to allow inverter DC bus capacitors (380V DC) to bleed down.
  • !Verify 0V DC across inverter filter capacitors before unplugging motor harness connectors.
  • !Keep hands clear of drive belt and pulleys during any manual rotation tng.
3. Preliminary Mechanical & Visual Checks
  • Slip off drive belt and spin drum/motor shaft by hand to check for roaring or seized ball bearings.
  • For universal motors: verify carbon brushes have at least 10mm remaining length and smooth contact faces.
  • Inspect motor suspension rubber mounts and drive belt tension/groove profile.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bosch E107

FAQ TREE
What does error code E107 mean on a Bosch appliance?

Bosch error code E107 indicates: The door does not open because it is locked. The display shows "Oven not unlocked"..

What is the root cause of Bosch error code E107?

The primary root cause for Bosch code E107 is: A door lock produced up to FD9103 had geometry that caused the hook to rub against the door insert, blocking movement. This prevented correct actuation of the microswitches, leading the electronics to detect an incorrect switching position..

How do I fix or resolve Bosch error code E107?

To resolve error code E107: Check if there is blocking of the lock and support of the lock; Motor lock: connection and cable controller; Engine changer lock; Check wiring according to diagram, correct; Correct position of micro-switches on the support frame; Change micro-switch; Change control module

Is it safe to clear Bosch error code E107 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E107 persists, the physical component causing A door lock produced up to FD9103 had geometry that caused the hook to rub against the door insert, blocking movement. This prevented correct actuation of the microswitches, leading the electronics to detect an incorrect switching position. must be inspected or replaced.

How do I test electrical resistance for Bosch code E107 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test 3-Phase Motor Windings / Tacho Generator / Carbon Brushes across Across phase pins U-V, V-W, U-W on motor harness; across tacho pins. Expected nominal reading is 3Ω–6Ω (BLDC phase U-V-W) / 60Ω–180Ω (Tacho coil) / 1.5Ω–3.5Ω (Universal stator). Tolerance: BLDC phase winding values must be strictly balanced within ±0.3Ω. Hand rotation generates 1V–4V AC on tacho..

What safety protocol must be followed before servicing Bosch code E107?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // BOSCH

Related Bosch Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E115General System & Mechanical Integration
Appliance main switch relay turns off and the appliance switches to a functionally safe state.
Inspect Protocol
E136NTC Temperature Sensor & Thermistor
Inverter temperature (IGBT) is three times higher
Inspect Protocol
E137Heating Element, Thermostat & Safety Fuse
Microwave inverter IGBT power transistor over-temperature safety shutdown.
Inspect Protocol
E138Drive Motor, Inverter & Tachometer Sensor
Inverter “Connector Error” H 95
Inspect Protocol
E139Drive Motor, Inverter & Tachometer Sensor
Invert “Fault in Control IC” H 96-1
Inspect Protocol
E140Drive Motor, Inverter & Tachometer Sensor
Invert “Fault in Control IC” H 96-2
Inspect Protocol
E141Drive Motor, Inverter & Tachometer Sensor
Inverter “Control Error” H 97
Inspect Protocol
E142Drive Motor, Inverter & Tachometer Sensor
Bosch E142: Motor drive or inverter rotation anomaly in Oven / Microwave; drum/motor fails t...
Inspect Protocol
E143Drive Motor, Inverter & Tachometer Sensor
Pulses from the inverter H 99
Inspect Protocol
E144Electronic Control Board (PCB) & Bus Communications
Plausibility check (Double ovens --> Oven cavity 1)
Inspect Protocol
E244Electronic Control Board (PCB) & Bus Communications
Plausibility check (Double ovens --> Oven cavity 2)
Inspect Protocol
E300Electronic Control Board (PCB) & Bus Communications
Unsatisfactory baking result or functions of the buttons do not correspond, appliance is in ...
Inspect Protocol
E303Electronic Control Board (PCB) & Bus Communications
The control board temperature is too high
Inspect Protocol
E305Electronic Control Board (PCB) & Bus Communications
Oven light flashes or the operating module is without function. The display flickers, and di...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy