Siemens E10 — Dishwasher
[ACTIVE]Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Scale build-up on heating element E10; reduced heat transfer efficiency and slow water temperature rise.
On Siemens dishwashers: Heavy lime scale deposit insulating heating element surface, depleted softening salt in ion exchanger, or hard water setting wrong.
Refill salt container with coarse dishwasher salt. Run intensive descaling cycle with citric acid descaler. Check hardness setting according to local water supply. Press and hold Start button for 4 seconds until display indicates '0:01', wait for evacuation pump, then power off.