Siemens E28 — Dishwasher
[ACTIVE]Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Turbidity AquaSensor optical calibration fault E28; phototransistor cannot calibrate wash water clarity.
On Siemens dishwashers: Lime or greasy film coating optical lenses in sump sensor, defective infrared emitter diode, or loose sensor harness.
Clean optical window of AquaSensor located in bottom of sump with soft cloth. Check 5V DC supply and signal wire continuity to main PCB. Press and hold Start button for 4 seconds until display indicates '0:01', wait for evacuation pump, then power off.