Zanussi E58 — Dryer
[ACTIVE]Zanussi AutoSense / ZDH Series Condenser Dryer: Heat pump compressor phase current exceeded E58 (> 4.5A); drive board limits frequency to prevent inverter thermal destruction.
On Zanussi (Zanussi AutoSense / ZDH Series Condenser Dryer) models: Extreme refrigeration circuit load due to saturated air filters, failing compressor capacitor (on non-inverter models) or internal piston friction.
Clean dual lint filters under running water and let dry completely. Vacuum heat exchanger duct. Measure live running current with clamp meter. Hold Start/Pause plus Skip/Option button simultaneously for 5 seconds until three rapid confirmation beeps clear persistent error memory.