Zanussi E59 — Dryer
[ACTIVE]Zanussi AutoSense / ZDH Series Condenser Dryer: No tachogenerator feedback signal E59; drum motor stops after 5 seconds of unmonitored rotation attempt.
On Zanussi (Zanussi AutoSense / ZDH Series Condenser Dryer) models: Detached or cracked tacho ring magnet on motor shaft, open tachogenerator coil (nominal 115–220 Ω), or disconnected wiring to inverter/main board.
Measure tachogenerator coil resistance across motor pins (115–220 Ω). Rotate motor pulley by hand while measuring AC millivolts (1–3V AC). Hold Start/Pause plus Skip/Option button simultaneously for 5 seconds until three rapid confirmation beeps clear persistent error memory.