Zanussi E60 — Dryer
[ACTIVE]Zanussi AutoSense / ZDH Series Condenser Dryer: Heating system general failure E60; air inside drum remains cold and cycle runs excessively long without drying clothes.
On Zanussi (Zanussi AutoSense / ZDH Series Condenser Dryer) models: Open heating element coils (dual element: ~25 Ω and ~35 Ω), tripped manual/automatic safety thermostat, defective heating relay on PCB, or compressor fault in heat pump.
Disconnect dryer and remove rear heating duct cover. Measure resistance of both heating elements with ohmmeter. Check continuity through safety thermostats (< 1 Ω). Hold Start/Pause plus Skip/Option button simultaneously for 5 seconds until three rapid confirmation beeps clear persistent error memory.