DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Amana UV
FAQ TREEWhat does error code UV mean on a Amana appliance?
Amana error code UV indicates: Amana Temp Assure Side-by-Side & Bottom-Mount Refrigerator: Diagnostic code UV indicates inverter driver DC link under-voltage trip; compressor cannot maintain required torque..
What is the root cause of Amana error code UV?
The primary root cause for Amana code UV is: On Amana refrigerators (Amana Temp Assure and Jazz electronic control platform): Grid brownout drop below 180V AC, high-resistance wall outlet plug, or dried-out electrolytic reservoir capacitors (< 210V DC bus)..
How do I fix or resolve Amana error code UV?
To resolve error code UV: Verify line voltage under compressor startup load (min 207V AC). Check DC bus voltage on inverter board (trip occurs below 210V DC). Replace inverter board if supply is 230V AC. Press and hold Refrigerator Temp and Freezer Temp adjustment buttons simultaneously for 3 seconds to reset Jazz board.
Is it safe to clear Amana error code UV by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Amana code UV persists, the physical component causing On Amana refrigerators (Amana Temp Assure and Jazz electronic control platform): Grid brownout drop below 180V AC, high-resistance wall outlet plug, or dried-out electrolytic reservoir capacitors (< 210V DC bus). must be inspected or replaced.
How do I test electrical resistance for Amana code UV using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..
What safety protocol must be followed before servicing Amana code UV?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.