Ariston F15 — Dishwasher
[ACTIVE]Ariston Hotpoint-Ariston 3D Zone Wash MaxiSpace Dishwasher: Circulation pump motor Hall sensor disconnect F15; inverter control board loses position pulse feedback from BLDC stator.
On Ariston dishwashers: Defective Hall IC on pump rear circuit, loose 3-wire signal plug on DEA700 power module, or moisture ingress into sensor cavity.
Inspect 3-wire Hall sensor connector on circulation pump and main PCB. Check 5V DC supply to sensor. If wiring intact and error persists, replace circulation pump. Hold Start/Reset key for 5 seconds until cycle cancel chime sounds and drain pump completes sump evacuation.