Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Arthur Martin AL6
FAQ TREEWhat does error code AL6 mean on a Arthur Martin appliance?
Arthur Martin error code AL6 indicates: Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher: Water heating failure AL6 (legacy EDW1500 alphanumeric); wash temperature fails to rise..
What is the root cause of Arthur Martin error code AL6?
The primary root cause for Arthur Martin code AL6 is: On Arthur Martin (Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher) models: Open heating element (nominal 25–28 Ω), tripped Klixon safety thermostat on heater casing, or open heating relay contact on PCB..
How do I fix or resolve Arthur Martin error code AL6?
To resolve error code AL6: Measure resistance across heating element terminals (25–28 Ω). Check continuity of safety Klixon (< 1 Ω). Resolder relay contacts on PCB. Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.
Is it safe to clear Arthur Martin error code AL6 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Arthur Martin code AL6 persists, the physical component causing On Arthur Martin (Arthur Martin ASF Series / Calypso / Electrolux Luxe Dishwasher) models: Open heating element (nominal 25–28 Ω), tripped Klixon safety thermostat on heater casing, or open heating relay contact on PCB. must be inspected or replaced.
How do I test electrical resistance for Arthur Martin code AL6 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Immersion / Air Heating Element & Klixon Thermostat across Between element terminals (unwired). Insulation to earth casing: >20MΩ (OL). Expected nominal reading is 25Ω–28Ω (230V / 2000W) / <0.5Ω (Safety Klixon closed). Tolerance: Formula R = V²/P (±5%). Any earth leakage reading below 2MΩ will trip the domestic 30mA RCD breaker..
What safety protocol must be followed before servicing Arthur Martin code AL6?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?