Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure AL6
FAQ TREEWhat does error code AL6 mean on a Faure appliance?
Faure error code AL6 indicates: Faure FDF Series / Clean&Dry / MaxiWash Dishwasher: Water heating failure AL6 (legacy EDW1500 alphanumeric); wash temperature fails to rise..
What is the root cause of Faure error code AL6?
The primary root cause for Faure code AL6 is: On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: Open heating element (nominal 25–28 Ω), tripped Klixon safety thermostat on heater casing, or open heating relay contact on PCB..
How do I fix or resolve Faure error code AL6?
To resolve error code AL6: Measure resistance across heating element terminals (25–28 Ω). Check continuity of safety Klixon (< 1 Ω). Resolder relay contacts on PCB. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code AL6 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code AL6 persists, the physical component causing On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: Open heating element (nominal 25–28 Ω), tripped Klixon safety thermostat on heater casing, or open heating relay contact on PCB. must be inspected or replaced.
How do I test electrical resistance for Faure code AL6 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Immersion / Air Heating Element & Klixon Thermostat across Between element terminals (unwired). Insulation to earth casing: >20MΩ (OL). Expected nominal reading is 25Ω–28Ω (230V / 2000W) / <0.5Ω (Safety Klixon closed). Tolerance: Formula R = V²/P (±5%). Any earth leakage reading below 2MΩ will trip the domestic 30mA RCD breaker..
What safety protocol must be followed before servicing Faure code AL6?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?