Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure I22
FAQ TREEWhat does error code I22 mean on a Faure appliance?
Faure error code I22 indicates: Faure FDF Series / Clean&Dry / MaxiWash Dishwasher: Siphon pressure sensor alarm i22; analog sensor detects back-pressure after drain cycle completes..
What is the root cause of Faure error code I22?
The primary root cause for Faure code I22 is: On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: Kitchen sink siphon spigot not drilled out on new installation, grease blockage in drain hose non-return flap, or restricted wall pipe..
How do I fix or resolve Faure error code I22?
To resolve error code I22: Inspect connection spigot under kitchen sink (ensure plastic membrane was drilled out). Clean rubber non-return flap in sump outlet. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code I22 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code I22 persists, the physical component causing On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: Kitchen sink siphon spigot not drilled out on new installation, grease blockage in drain hose non-return flap, or restricted wall pipe. must be inspected or replaced.
How do I test electrical resistance for Faure code I22 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Faure code I22?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



