DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Arthur Martin F106
FAQ TREEWhat does error code F106 mean on a Arthur Martin appliance?
Arthur Martin error code F106 indicates: Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Heating safety relay welded F106; main PCB detects continuity through heating element relay contacts when deactivated..
What is the root cause of Arthur Martin error code F106?
The primary root cause for Arthur Martin code F106 is: On Arthur Martin (Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven) models: Electrical arcing welded the 16A relay contacts on the power PCB, or transient voltage spike degraded the relay coil switching driver..
How do I fix or resolve Arthur Martin error code F106?
To resolve error code F106: Disconnect oven mains immediately. Inspect relay contacts on power PCB with ohmmeter (must read ∞ Ω open circuit when unpowered). Replace PCB or relay. Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.
Is it safe to clear Arthur Martin error code F106 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Arthur Martin code F106 persists, the physical component causing On Arthur Martin (Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven) models: Electrical arcing welded the 16A relay contacts on the power PCB, or transient voltage spike degraded the relay coil switching driver. must be inspected or replaced.
How do I test electrical resistance for Arthur Martin code F106 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Immersion / Air Heating Element & Klixon Thermostat across Between element terminals (unwired). Insulation to earth casing: >20MΩ (OL). Expected nominal reading is 25Ω–28Ω (230V / 2000W) / <0.5Ω (Safety Klixon closed). Tolerance: Formula R = V²/P (±5%). Any earth leakage reading below 2MΩ will trip the domestic 30mA RCD breaker..
What safety protocol must be followed before servicing Arthur Martin code F106?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.