Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEF109
Arthur Martin
Arthur Martin // OFFICIAL DIAGNOSTIC BENCH

Arthur Martin F109

OvenNTC Temperature Sensor & Thermistor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Other Brands Sharing Code F109:MieleF109ElectroluxF109AEGF109ZanussiF109CastorF109FaureF109FrigidaireF109KelvinatorF109WestinghouseF109ZoppasF109

Symptom / Description

FAULT

Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Cavity temperature sensor fault F109; electronic board detects open circuit or shorted PT500 / PT1000 temperature sensor.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Arthur Martin (Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven) models: Open platinum thermal sensor element in oven back wall (nominal ~540 Ω for PT500 or ~1080 Ω for PT1000 at 20°C), broken wiring lead, or pinched heat-resistant cable.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect oven mains. Access rear panel cavity sensor harness. Measure resistance with multimeter (PT500 reads ~540 Ω at 20°C; PT1000 reads ~1080 Ω at 20°C). Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Arthur Martin Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Arthur Martin F109

FAQ TREE
What does error code F109 mean on a Arthur Martin appliance?

Arthur Martin error code F109 indicates: Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Cavity temperature sensor fault F109; electronic board detects open circuit or shorted PT500 / PT1000 temperature sensor..

What is the root cause of Arthur Martin error code F109?

The primary root cause for Arthur Martin code F109 is: On Arthur Martin (Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven) models: Open platinum thermal sensor element in oven back wall (nominal ~540 Ω for PT500 or ~1080 Ω for PT1000 at 20°C), broken wiring lead, or pinched heat-resistant cable..

How do I fix or resolve Arthur Martin error code F109?

To resolve error code F109: Disconnect oven mains. Access rear panel cavity sensor harness. Measure resistance with multimeter (PT500 reads ~540 Ω at 20°C; PT1000 reads ~1080 Ω at 20°C). Hold Départ/Pause and Option buttons firmly for 5 seconds until the red indicator extinguishes and service memory resets.

Is it safe to clear Arthur Martin error code F109 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Arthur Martin code F109 persists, the physical component causing On Arthur Martin (Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven) models: Open platinum thermal sensor element in oven back wall (nominal ~540 Ω for PT500 or ~1080 Ω for PT1000 at 20°C), broken wiring lead, or pinched heat-resistant cable. must be inspected or replaced.

How do I test electrical resistance for Arthur Martin code F109 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Arthur Martin code F109?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ARTHUR MARTIN

Related Arthur Martin Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

F110Drive Motor, Inverter & Tachometer Sensor
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Door lock position mismatch F110...
Inspect Protocol
F111Heating Element, Thermostat & Safety Fuse
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Heating rise timeout F111; oven ...
Inspect Protocol
F112Electronic Control Board (PCB) & Bus Communications
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Appliance EEPROM configuration e...
Inspect Protocol
F101Drive Motor, Inverter & Tachometer Sensor
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Door lock motorized latch error ...
Inspect Protocol
F102Drive Motor, Inverter & Tachometer Sensor
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Door unlock timeout F102; pyroly...
Inspect Protocol
F103Drive Motor, Inverter & Tachometer Sensor
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Tangential cooling fan speed err...
Inspect Protocol
F104Electronic Control Board (PCB) & Bus Communications
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Electronic control board over-te...
Inspect Protocol
F105NTC Temperature Sensor & Thermistor
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Food meat probe circuit error F1...
Inspect Protocol
F106Heating Element, Thermostat & Safety Fuse
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Heating safety relay welded F106...
Inspect Protocol
F107Electronic Control Board (PCB) & Bus Communications
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Internal communication link erro...
Inspect Protocol
F108Heating Element, Thermostat & Safety Fuse
Arthur Martin AOB Series / Pyrolyse Chaleur Tournante Oven: Electrical mains frequency error...
Inspect Protocol
E0Electronic Control Board (PCB) & Bus Communications
Arthur Martin TIG / TI Series / Induction Maestro Cooktop: Electronic sub-bus communication ...
Inspect Protocol
E1Water Level Pressure Switch & Air Dome
Arthur Martin TIG / TI Series / Induction Maestro Cooktop: Touch control surface blocked E1;...
Inspect Protocol
E2NTC Temperature Sensor & Thermistor
Arthur Martin TIG / TI Series / Induction Maestro Cooktop: Induction coil overheating alarm ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy