Bosch E27 — Dishwasher
[ACTIVE]Bosch Serie 4 / Serie 6 / Serie 8 ActiveWater & PerfectDry Zeolith: Mains undervoltage detected E27; AC supply voltage drops below minimum operating threshold (< 190V AC).
On Bosch dishwashers: Household electrical grid overloaded by heavy appliances, thin extension cord, loose neutral terminal in socket, or utility power dip.
Plug dishwasher directly into dedicated 16A grounded wall socket (do not use extension cords). Measure AC voltage at outlet (must be 220–240V AC). Hold Start/Reset key for 3 seconds until '0:01' appears, close door, allow 60s for drain completion, then power off.