Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE5
Candy
Candy // OFFICIAL DIAGNOSTIC BENCH

Candy Dishwasher E5

DishwasherNTC Temperature Sensor & Thermistor
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
HaierE5HooverE5RosièresE5ZerowattE5IbernaE5GEE5
Other Brands Sharing Code E5:BoschE5SiemensE5LGE5WhirlpoolE5ElectroluxE5AEGE5BekoE5IndesitE5BauknechtE5

Symptom / Description

FAULT

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Wash water temperature NTC sensor error E5; thermistor reading open-circuit or short-circuit outside allowable range.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Candy dishwashers powered by Brava high-pressure wash hydraulics, Maxi Tub basket architecture, and Smart Touch / hOn Wi-Fi telemetry: Defective NTC thermistor bead in sump, corroded connector terminals from detergent seepage, or damaged wiring harness.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect NTC connector at sump. Measure thermistor resistance (nominal ~47 kΩ at 25°C or ~10 kΩ depending on platform). Replace probe if open. Press and hold Start/Reset for 5 seconds until the LED rapid flash ends, close door to initiate 60s drain cycle, then power off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Candy Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Thermal & Heating Loop

Calrod Heating Element R1, Safety Klixon & NTC Thermistor Probe

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III24.6 ΩVΩCOMHEATING ELEMENT R1HEATER R1: 20-28 ΩSAFETY THERMOSTAT (KLIXON)NTC SENSOR (4.8-12kΩ)
Target Component
NTC Temperature Sensor Probe (Thermistor)
Nominal Resistance / Test Range
4.8kΩ–12kΩ (at 20°C–25°C)
Test Harness Pins
Across sensor pins 1-2 (unplugged harness)
Diagnostic Verification Rule
Zero or OL indicates open heating element or tripped safety thermostat. Check insulation to earth.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Candy E5

FAQ TREE
What does error code E5 mean on a Candy appliance?

Candy error code E5 indicates: Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Wash water temperature NTC sensor error E5; thermistor reading open-circuit or short-circuit outside allowable range..

What is the root cause of Candy error code E5?

The primary root cause for Candy code E5 is: On Candy dishwashers powered by Brava high-pressure wash hydraulics, Maxi Tub basket architecture, and Smart Touch / hOn Wi-Fi telemetry: Defective NTC thermistor bead in sump, corroded connector terminals from detergent seepage, or damaged wiring harness..

How do I fix or resolve Candy error code E5?

To resolve error code E5: Disconnect NTC connector at sump. Measure thermistor resistance (nominal ~47 kΩ at 25°C or ~10 kΩ depending on platform). Replace probe if open. Press and hold Start/Reset for 5 seconds until the LED rapid flash ends, close door to initiate 60s drain cycle, then power off.

Is it safe to clear Candy error code E5 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Candy code E5 persists, the physical component causing On Candy dishwashers powered by Brava high-pressure wash hydraulics, Maxi Tub basket architecture, and Smart Touch / hOn Wi-Fi telemetry: Defective NTC thermistor bead in sump, corroded connector terminals from detergent seepage, or damaged wiring harness. must be inspected or replaced.

How do I test electrical resistance for Candy code E5 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Candy code E5?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Candy error code E5 mean on a Dishwasher?

Candy error code E5 on a Dishwasher indicates: Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Wash water temperature NTC sensor error E5; thermistor reading open-circuit or short-circuit outside allowable range.. Primary cause: On Candy dishwashers powered by Brava high-pressure wash hydraulics, Maxi Tub basket architecture, and Smart Touch / hOn Wi-Fi telemetry: Defective NTC thermistor bead in sump, corroded connector terminals from detergent seepage, or damaged wiring harness.. Recommended solution: Disconnect NTC connector at sump. Measure thermistor resistance (nominal ~47 kΩ at 25°C or ~10 kΩ depending on platform). Replace probe if open. Press and hold Start/Reset for 5 seconds until the LED rapid flash ends, close door to initiate 60s drain cycle, then power off..

What does Candy error code E5 mean on a Hob?

Candy error code E5 on a Hob indicates: Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply overvoltage fault E5; input AC voltage exceeds safe operating limit (>275V AC).. Primary cause: On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Incorrect 400V connection without neutral, floating neutral line in household breaker panel, or electrical storm surge.. Recommended solution: Immediately turn off circuit breaker. Measure voltage between Live (L1/L2) and Neutral (N) at terminal block (must be 230V AC; if ~400V AC, neutral is missing). Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds..

What does Candy error code E5 mean on a Refrigerator / Freezer?

Candy error code E5 on a Refrigerator / Freezer indicates: Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Convertible zone temperature sensor fault E5; MyZone / Flex drawer thermistor sensing circuit failed.. Primary cause: On Candy refrigeration units featuring Fresco Total No-Frost dual-circulation cooling, multi-sensor temperature regulation, and inverter compressor: Drawer slide mechanical abrasion against sensor cable, condensation in sensor pocket, or open thermistor.. Recommended solution: Remove convertible drawer and inspect NTC harness behind air duct. Measure ~5 kΩ at 25°C and ~16 kΩ at 0°C. Replace damaged sensor loom. Reset: Press and hold Temp Set and Super Cool buttons together for 8 seconds until the display chime signals memory clear, then release..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Candy E5 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Candy E5 — Dishwasher

[ACTIVE]
Symptom / Description:

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Wash water temperature NTC sensor error E5; thermistor reading open-circuit or short-circuit outside allowable range.

Root Cause:

On Candy dishwashers powered by Brava high-pressure wash hydraulics, Maxi Tub basket architecture, and Smart Touch / hOn Wi-Fi telemetry: Defective NTC thermistor bead in sump, corroded connector terminals from detergent seepage, or damaged wiring harness.

Repair Instructions:

Disconnect NTC connector at sump. Measure thermistor resistance (nominal ~47 kΩ at 25°C or ~10 kΩ depending on platform). Replace probe if open. Press and hold Start/Reset for 5 seconds until the LED rapid flash ends, close door to initiate 60s drain cycle, then power off.

Candy E5 — Hob

Symptom / Description:

Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply overvoltage fault E5; input AC voltage exceeds safe operating limit (>275V AC).

Root Cause:

On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Incorrect 400V connection without neutral, floating neutral line in household breaker panel, or electrical storm surge.

Repair Instructions:

Immediately turn off circuit breaker. Measure voltage between Live (L1/L2) and Neutral (N) at terminal block (must be 230V AC; if ~400V AC, neutral is missing). Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.

Candy E5 — Refrigerator / Freezer

Symptom / Description:

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Convertible zone temperature sensor fault E5; MyZone / Flex drawer thermistor sensing circuit failed.

Root Cause:

On Candy refrigeration units featuring Fresco Total No-Frost dual-circulation cooling, multi-sensor temperature regulation, and inverter compressor: Drawer slide mechanical abrasion against sensor cable, condensation in sensor pocket, or open thermistor.

Repair Instructions:

Remove convertible drawer and inspect NTC harness behind air duct. Measure ~5 kΩ at 25°C and ~16 kΩ at 0°C. Replace damaged sensor loom. Reset: Press and hold Temp Set and Super Cool buttons together for 8 seconds until the display chime signals memory clear, then release.

SEMANTIC KNOWLEDGE GRAPH // CANDY

Related Candy Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E6Dishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Controller EEPROM memory error E6; mic...
Inspect Protocol
E7Dishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Wash circulation pump failure E7; moto...
Inspect Protocol
E8Dishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Wash heating circuit failure E8; water...
Inspect Protocol
E9Dishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Turbidity optical sensor fault E9; inf...
Inspect Protocol
EdDishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Detergent dispenser actuator fault Ed;...
Inspect Protocol
EFDishwasher
Water Level Pressure Switch & Air Dome
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Flowmeter pulse overflow anomaly EF; i...
Inspect Protocol
EhDishwasher
NTC Temperature Sensor & Thermistor
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Heating circuit safety thermal overhea...
Inspect Protocol
ELDishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Low incoming water pressure detected E...
Inspect Protocol
AL03Dishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Drain evacuation alarm AL03; sump fail...
Inspect Protocol
AL05Dishwasher
Water Level Pressure Switch & Air Dome
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Water filling timeout alarm AL05; wash...
Inspect Protocol
E01Dishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Water fill solenoid valve circuit faul...
Inspect Protocol
E02Dishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Fill meter pulse count error E02; turb...
Inspect Protocol
E03Dishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Drain pump evacuation timeout E03; wat...
Inspect Protocol
E04Dishwasher
Drainage System & Drain Pump
Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Bottom tray anti-flood switch activate...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy