OEM VERIFIED BENCH
OFFICIAL FAULT CODESTOP
Candy
Candy // OFFICIAL DIAGNOSTIC BENCH

Candy Oven STOP

OvenDoor Lock Mechanism & Safety Interlock
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Haier / Candy / Hoover / GE Group: Equivalent Code Across OEM Group Brands
Haier Europe / Candy-Hoover Shared Electronic Platform
HooverSTOPRosieresSTOPZerowattSTOPBaumaticSTOP
Other Brands Sharing Code STOP:IndesitSTOPBauknechtSTOPAristonSTOPSauterSTOPScholtèsSTOPSchaub LorenzSTOPArdoSTOP

Symptom / Description

FAULT

STOP message displayed, often during pyrolytic cleaning

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The required conditions for a function (like self-cleaning) are not met. This is usually due to the door not being properly locked.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Ensure the oven door is fully closed and the lock has engaged. If the door is locked and the error persists, there may be a fault with the door lock switch.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Candy Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Door Interlock & Triac Loop

PTC Bi-metal Solenoid L1, Microswitch S1 & PCB Switching Triac TY1

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III320.0 ΩVΩCOMDOOR INTERLOCK L1PTC / SOLENOID COIL L1LOCKING BOLT PINSAFETY MICROSWITCH S1
Target Component
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Nominal Resistance / Test Range
800Ω–1.5kΩ (PTC terminals L-N) / 60Ω–120Ω (Pulse Solenoid)
Test Harness Pins
Across PTC heater terminals on lock bezel; switch contact reads <0.2Ω when locked
Diagnostic Verification Rule
High resistance (> 2 kΩ) or failed contact closure prevents cycle initiation and locks MCU bus.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDoor Lock Mechanism & Safety InterlockOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
800Ω–1.5kΩ (PTC terminals L-N) / 60Ω–120Ω (Pulse Solenoid)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Test Pins & Connections
PROBE (+)
PROBE (-)
Across PTC heater terminals on lock bezel; switch contact reads <0.2Ω when locked
Tolerance & Diagnostic Criteria±15%. Switch contacts must read open (OL) when unlocked and 0.0Ω–0.2Ω when fully latched.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V mains power before releasing door gasket clamp or lock retaining screws.
  • !Never short-circuit or bypass the safety door lock contacts: severe hazard of rotating drum exposure or fire.
  • !Keep fingers away from spring-loaded latch mechanisms during closure cycling.
3. Preliminary Mechanical & Visual Checks
  • Inspect door strike pin and handle latch hook for plastic deformation, breakage, or misalignment.
  • Check door hinge alignment: a sagging door prevents the latch tongue from engaging the safety microswitch.
  • Locate and verify emergency manual pull cord inside the lower drain pump hatch.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Candy STOP

FAQ TREE
What does error code STOP mean on a Candy appliance?

Candy error code STOP indicates: STOP message displayed, often during pyrolytic cleaning.

What is the root cause of Candy error code STOP?

The primary root cause for Candy code STOP is: The required conditions for a function (like self-cleaning) are not met. This is usually due to the door not being properly locked..

How do I fix or resolve Candy error code STOP?

To resolve error code STOP: Ensure the oven door is fully closed and the lock has engaged. If the door is locked and the error persists, there may be a fault with the door lock switch.

Is it safe to clear Candy error code STOP by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Candy code STOP persists, the physical component causing The required conditions for a function (like self-cleaning) are not met. This is usually due to the door not being properly locked. must be inspected or replaced.

How do I test electrical resistance for Candy code STOP using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts across Across PTC heater terminals on lock bezel; switch contact reads <0.2Ω when locked. Expected nominal reading is 800Ω–1.5kΩ (PTC terminals L-N) / 60Ω–120Ω (Pulse Solenoid). Tolerance: ±15%. Switch contacts must read open (OL) when unlocked and 0.0Ω–0.2Ω when fully latched..

What safety protocol must be followed before servicing Candy code STOP?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // CANDY

Related Candy Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

Er01Oven
NTC Temperature Sensor & Thermistor
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity temperature sensor open circui...
Inspect Protocol
Er02Oven
NTC Temperature Sensor & Thermistor
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity temperature sensor short circu...
Inspect Protocol
Er03Oven
Heating Element, Thermostat & Safety Fuse
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity overtemperature condition Er03...
Inspect Protocol
Er04Oven
Drive Motor, Inverter & Tachometer Sensor
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Tangential cooling fan failure Er04; ...
Inspect Protocol
Er05Oven
Drive Motor, Inverter & Tachometer Sensor
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Pyrolysis door lock latch failure Er0...
Inspect Protocol
Er06Oven
Drive Motor, Inverter & Tachometer Sensor
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Pyrolysis door unlock timeout Er06; m...
Inspect Protocol
Er07Oven
NTC Temperature Sensor & Thermistor
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Food meat probe circuit fault Er07; i...
Inspect Protocol
Er08Oven
Heating Element, Thermostat & Safety Fuse
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Power relay board communication lost ...
Inspect Protocol
Er09Oven
Water Level Pressure Switch & Air Dome
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Stuck touch control key error Er09; c...
Inspect Protocol
Er15Oven
NTC Temperature Sensor & Thermistor
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Electronics housing ambient overtempe...
Inspect Protocol
Er20Oven
Electronic Control Board (PCB) & Bus Communications
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Microcontroller flash memory checksum...
Inspect Protocol
Er21Oven
Electronic Control Board (PCB) & Bus Communications
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Low-voltage DC power supply ripple fa...
Inspect Protocol
Er22Oven
Electronic Control Board (PCB) & Bus Communications
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Touch control panel matrix evaluation...
Inspect Protocol
Er31Oven
Electronic Control Board (PCB) & Bus Communications
Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Appliance variant model configuration...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy