Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faber AL01
FAQ TREEWhat does error code AL01 mean on a Faber appliance?
Faber error code AL01 indicates: Faber FreshTech Total No-Frost Integrated Built-in Refrigerator-Freezer: Diagnostic fault code AL01 registered by the microcomputer controller. Door ajar alarm timeout exceeded (> 3 minutes open)..
What is the root cause of Faber error code AL01?
The primary root cause for Faber code AL01 is: On Faber appliances engineered with FreshTech dual airflow multi-zone distribution, digital inverter compressor, and rapid freeze evaporator defrost system: refrigerator or freezer door left open or switch stuck. Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 2.5 kΩ at 60°C..
How do I fix or resolve Faber error code AL01?
To resolve error code AL01: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across 2-pin harness connector (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold the Super Freeze and Alarm Mute buttons simultaneously for 5 seconds until a long beep sounds, indicating the temperature sensor fault code has been cleared and cooling logic reset.
Is it safe to clear Faber error code AL01 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faber code AL01 persists, the physical component causing On Faber appliances engineered with FreshTech dual airflow multi-zone distribution, digital inverter compressor, and rapid freeze evaporator defrost system: refrigerator or freezer door left open or switch stuck. Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 2.5 kΩ at 60°C. must be inspected or replaced.
How do I test electrical resistance for Faber code AL01 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..
What safety protocol must be followed before servicing Faber code AL01?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



