OFFICIAL FAULT CODEAL01
Miele
Miele // OFFICIAL DIAGNOSTIC BENCH

Miele AL01

RefrigeratorRefrigeration Compressor, Defrost Heater & PTC Relay
Monolithic French-door smart refrigerator in matte black steel with dual refrigeration zones
Refrigerator
Other Brands Sharing Code AL01:IndesitAL01BauknechtAL01V-ZugAL01De DietrichAL01LiebherrAL01GaggenauAL01SchulthessAL01FAGORAL01RosieresAL01SauterAL01

Symptom / Description

FAULT

Refrigerator compartment too warm

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

The refrigerator temperature has been too high for an extended period. The door may have been left open, or there is a cooling system fault.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Ensure the door is properly closed and that vents are not blocked. Check door seals for damage. If the temperature does not drop, it may indicate a sealed system issue requiring a technician.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Miele Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLRefrigeration Compressor, Defrost Heater & PTC RelayRefrigerator / Freezer
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Compressor Motor Windings (Run/Start) & Defrost Heater
Test Pins & Connections
PROBE (+)
PROBE (-)
Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).
Tolerance & Diagnostic Criteria±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero.
1. Pre-Intervention Electrical Safety Protocols
  • !Refrigeration Safety Protocol: Disconnect mains power before unclipping compressor terminal covers.
  • !Flammable Refrigerant Warning: R600a (isobutane) is flammable. Never puncture cooling tubes or use open flame.
  • !High Surface Temperature: Compressor shell can exceed 80°C during normal operation. Allow to cool before inspection.
3. Preliminary Mechanical & Visual Checks
  • Listen for compressor startup attempts: repetitive clicking every 60 seconds indicates locked rotor or failed PTC relay.
  • Inspect evaporator coil for thick solid frost buildup, signaling defrost heater, sensor, or timer failure.
  • Clean condenser coils and check cooling fan motor for free rotation and dust accumulation.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Miele AL01

FAQ TREE
What does error code AL01 mean on a Miele appliance?

Miele error code AL01 indicates: Refrigerator compartment too warm.

What is the root cause of Miele error code AL01?

The primary root cause for Miele code AL01 is: The refrigerator temperature has been too high for an extended period. The door may have been left open, or there is a cooling system fault..

How do I fix or resolve Miele error code AL01?

To resolve error code AL01: Ensure the door is properly closed and that vents are not blocked. Check door seals for damage. If the temperature does not drop, it may indicate a sealed system issue requiring a technician.

Is it safe to clear Miele error code AL01 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Miele code AL01 persists, the physical component causing The refrigerator temperature has been too high for an extended period. The door may have been left open, or there is a cooling system fault. must be inspected or replaced.

How do I test electrical resistance for Miele code AL01 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..

What safety protocol must be followed before servicing Miele code AL01?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // MIELE

Related Miele Refrigerator / Freezer Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

AL02Refrigeration Compressor, Defrost Heater & PTC Relay
Freezer compartment too warm
Inspect Protocol
F0NTC Temperature Sensor & Thermistor
Miele F0: NTC temperature sensor signal out of range (open or short circuit) in Refrigerator...
Inspect Protocol
F1NTC Temperature Sensor & Thermistor
Miele F1: NTC temperature sensor signal out of range (open or short circuit) in Refrigerator...
Inspect Protocol
F160NTC Temperature Sensor & Thermistor
Faulty cabinet temperature sensor signal in wine conditioning zone 1.
Inspect Protocol
F2Refrigeration Compressor, Defrost Heater & PTC Relay
Freezer evaporator sensor fault
Inspect Protocol
F3Electronic Control Board (PCB) & Bus Communications
Miele F3: Operational cycle fault detected during Refrigerator / Freezer program execution.
Inspect Protocol
F4NTC Temperature Sensor & Thermistor
Miele F4: NTC temperature sensor signal out of range (open or short circuit) in Refrigerator...
Inspect Protocol
Check DrainDrainage System & Drain Pump
Miele CHECK DRAIN: Water drainage failure detected in Washing Machine; drain pump cannot eva...
Inspect Protocol
Check InletWater Level Pressure Switch & Air Dome
Miele CHECK INLET: Water inlet / filling timeout in Washing Machine; appliance fails to fill...
Inspect Protocol
Clean plinth filterDoor Lock Mechanism & Safety Interlock
Reminder to clean heat exchanger filter
Inspect Protocol
DEElectronic Control Board (PCB) & Bus Communications
Communication error with power module
Inspect Protocol
F047NTC Temperature Sensor & Thermistor
Miele F047: NTC temperature sensor signal out of range (open or short circuit) in Tumble Dryer.
Inspect Protocol
F066Door Lock Mechanism & Safety Interlock
Insufficient air circulation
Inspect Protocol
F10Water Inlet Valve, Aquastop & Flowmeter
The appliance (washing machine/dishwasher) does not fill with water or filling is extremely ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy