Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Ariston AL01
FAQ TREEWhat does error code AL01 mean on a Ariston appliance?
Ariston error code AL01 indicates: Ariston Quadrio 4-Door Total NoFrost Refrigerator: Fresh food compartment evaporator NTC thermistor sensor fault AL01; circuit reading out of calibrated limits..
What is the root cause of Ariston error code AL01?
The primary root cause for Ariston code AL01 is: On Ariston refrigerators (Ariston Italian ergonomic chassis engineering and Bitron / EVO-II microprocessor bus platform): Water ingress into thermal sensor epoxy potting, fractured copper leads behind liner, or corrosion on terminal pin J1..
How do I fix or resolve Ariston error code AL01?
To resolve error code AL01: Unplug unit. Access sensor behind rear baffle. Measure NTC resistance: nominal ~2.7 kΩ at 25°C, ~7.8 kΩ at 4°C, ~16 kΩ at 0°C. Replace sensor probe. Press Alarm Reset button for 5 seconds to reset high-temperature acoustic warning and clear fault code.
Is it safe to clear Ariston error code AL01 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Ariston code AL01 persists, the physical component causing On Ariston refrigerators (Ariston Italian ergonomic chassis engineering and Bitron / EVO-II microprocessor bus platform): Water ingress into thermal sensor epoxy potting, fractured copper leads behind liner, or corrosion on terminal pin J1. must be inspected or replaced.
How do I test electrical resistance for Ariston code AL01 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..
What safety protocol must be followed before servicing Ariston code AL01?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?