DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Ignis AL01
FAQ TREEWhat does error code AL01 mean on a Ignis appliance?
Ignis error code AL01 indicates: Ignis Combi Double Door Total NoFrost Refrigerator: Fresh food compartment evaporator NTC thermistor sensor fault AL01; circuit reading out of calibrated limits..
What is the root cause of Ignis error code AL01?
The primary root cause for Ignis code AL01 is: On Ignis refrigerators (Ignis heavy-duty electromechanical chassis and Arcadia / L1373 hybrid control architecture): Water ingress into thermal sensor epoxy potting, fractured copper leads behind liner, or corrosion on terminal pin J1..
How do I fix or resolve Ignis error code AL01?
To resolve error code AL01: Unplug unit. Access sensor behind rear baffle. Measure NTC resistance: nominal ~2.7 kΩ at 25°C, ~7.8 kΩ at 4°C, ~16 kΩ at 0°C. Replace sensor probe. Press thermostat reset or super button for 3 seconds to cancel temperature alarm and re-arm cooling.
Is it safe to clear Ignis error code AL01 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Ignis code AL01 persists, the physical component causing On Ignis refrigerators (Ignis heavy-duty electromechanical chassis and Arcadia / L1373 hybrid control architecture): Water ingress into thermal sensor epoxy potting, fractured copper leads behind liner, or corrosion on terminal pin J1. must be inspected or replaced.
How do I test electrical resistance for Ignis code AL01 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Compressor Motor Windings (Run/Start) & Defrost Heater across Across 3 compressor pins (Common, Run, Start): R(C-S) + R(C-R) = R(S-R). Winding to earth: >20MΩ (OL).. Expected nominal reading is 15Ω–25Ω (Run C-R), 20Ω–35Ω (Start C-S), 200Ω–400Ω (Defrost Heater). PTC Relay: 10Ω–30Ω at 25°C.. Tolerance: ±10%. Any low insulation resistance to casing (<2MΩ) trips the breaker. Defrost bimetal reads <0.5Ω when sub-zero..
What safety protocol must be followed before servicing Ignis code AL01?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.