Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEd23
FAGOR
FAGOR // OFFICIAL DIAGNOSTIC BENCH

FAGOR Washing Machine d23

Washing MachineNTC Temperature Sensor & Thermistor
Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
Washing Machine
Brandt / Fagor Group: Equivalent Code Across OEM Group Brands
Groupe Brandt / Fagor Shared Electronic Platform
Brandtd23De Dietrichd23Sauterd23
Other Brands Sharing Code d23:OceanD23

Symptom / Description

FAULT

Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Condenser drying NTC thermistor fault d23; temperature sensing on the condensation duct fails verification.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On FAGOR washer-dryers featuring Innova electronic architecture, dual d01-d27 / F01-F15 diagnostic telemetry, and robust motor drive with 15mm carbon brushes: Open or shorted condenser NTC thermistor probe (~20 kΩ at 20°C, ~5 kΩ at 60°C), or moisture ingress in harness plug.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect sensor plug on condensation duct. Measure resistance (~20 kΩ at 20°C). Replace NTC sensor probe if reading is open or zero ohms. Turn selector dial to 0, press and hold Start/Pause and Extra Rinse buttons for 6 seconds until 'F00' or display resets, then restart.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide FAGOR Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Thermal & Heating Loop

Calrod Heating Element R1, Safety Klixon & NTC Thermistor Probe

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III24.6 ΩVΩCOMHEATING ELEMENT R1HEATER R1: 20-28 ΩSAFETY THERMOSTAT (KLIXON)NTC SENSOR (4.8-12kΩ)
Target Component
NTC Temperature Sensor Probe (Thermistor)
Nominal Resistance / Test Range
4.8kΩ–12kΩ (at 20°C–25°C)
Test Harness Pins
Across sensor pins 1-2 (unplugged harness)
Diagnostic Verification Rule
Zero or OL indicates open heating element or tripped safety thermostat. Check insulation to earth.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorWashing Machine
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: FAGOR D23

FAQ TREE
What does error code D23 mean on a FAGOR appliance?

FAGOR error code D23 indicates: Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Condenser drying NTC thermistor fault d23; temperature sensing on the condensation duct fails verification..

What is the root cause of FAGOR error code D23?

The primary root cause for FAGOR code D23 is: On FAGOR washer-dryers featuring Innova electronic architecture, dual d01-d27 / F01-F15 diagnostic telemetry, and robust motor drive with 15mm carbon brushes: Open or shorted condenser NTC thermistor probe (~20 kΩ at 20°C, ~5 kΩ at 60°C), or moisture ingress in harness plug..

How do I fix or resolve FAGOR error code D23?

To resolve error code D23: Disconnect sensor plug on condensation duct. Measure resistance (~20 kΩ at 20°C). Replace NTC sensor probe if reading is open or zero ohms. Turn selector dial to 0, press and hold Start/Pause and Extra Rinse buttons for 6 seconds until 'F00' or display resets, then restart.

Is it safe to clear FAGOR error code D23 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if FAGOR code D23 persists, the physical component causing On FAGOR washer-dryers featuring Innova electronic architecture, dual d01-d27 / F01-F15 diagnostic telemetry, and robust motor drive with 15mm carbon brushes: Open or shorted condenser NTC thermistor probe (~20 kΩ at 20°C, ~5 kΩ at 60°C), or moisture ingress in harness plug. must be inspected or replaced.

How do I test electrical resistance for FAGOR code D23 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing FAGOR code D23?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // FAGOR

Related FAGOR Washing Machine Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

d24Washing Machine
Drive Motor, Inverter & Tachometer Sensor
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Washer-dryer ventilation...
Inspect Protocol
d25Washing Machine
Drive Motor, Inverter & Tachometer Sensor
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Repetitive unbalance abo...
Inspect Protocol
d26Washing Machine
Drive Motor, Inverter & Tachometer Sensor
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: BLDC motor inverter over...
Inspect Protocol
d27Washing Machine
Water Level Pressure Switch & Air Dome
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Door unlock timeout at c...
Inspect Protocol
E04Washing Machine
Water Inlet Valve, Aquastop & Flowmeter
Fagor Basque Platform Washing Machine halts after 4 minutes with error 'E04' and empty drum ...
Inspect Protocol
F01Washing Machine
Water Inlet Valve, Aquastop & Flowmeter
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Basque electronic platfo...
Inspect Protocol
F06Washing Machine
Drive Motor, Inverter & Tachometer Sensor
Fagor Washing Machine display shows 'F06' during agitation; motor pauses repeatedly and fail...
Inspect Protocol
F07Washing Machine
Water Level Pressure Switch & Air Dome
Fagor Washing Machine stops and forces drain pump on with fault 'F07' displayed on LCD panel.
Inspect Protocol
F09Washing Machine
Electronic Control Board (PCB) & Bus Communications
Fagor Washing Machine display erratically flips cycle selections and displays 'F09' upon pre...
Inspect Protocol
d01Washing Machine
Water Level Pressure Switch & Air Dome
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Water intake timeout d01...
Inspect Protocol
d02Washing Machine
Drainage System & Drain Pump
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Drain pump timeout d02; ...
Inspect Protocol
d03Washing Machine
Heating Element, Thermostat & Safety Fuse
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Heating circuit timeout ...
Inspect Protocol
d04Washing Machine
Drive Motor, Inverter & Tachometer Sensor
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Motor drive electronic f...
Inspect Protocol
d05Washing Machine
NTC Temperature Sensor & Thermistor
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Wash NTC temperature sen...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy