Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure E72
FAQ TREEWhat does error code E72 mean on a Faure appliance?
Faure error code E72 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Drying condenser NTC sensor fault E72 on washer-dryer; condenser temperature feedback signal missing..
What is the root cause of Faure error code E72?
The primary root cause for Faure code E72 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Drying condenser NTC thermistor open or shorted (nominal 4.8–6.0 kΩ at 20°C), broken wiring harness to rear condenser, or disconnected plug..
How do I fix or resolve Faure error code E72?
To resolve error code E72: Access rear condenser duct. Unplug NTC and measure resistance with multimeter (expected 4.8–6.0 kΩ at 20°C). Check wiring continuity. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E72 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E72 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Drying condenser NTC thermistor open or shorted (nominal 4.8–6.0 kΩ at 20°C), broken wiring harness to rear condenser, or disconnected plug. must be inspected or replaced.
How do I test electrical resistance for Faure code E72 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Faure code E72?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?