DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure E73
FAQ TREEWhat does error code E73 mean on a Faure appliance?
Faure error code E73 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Drying air duct NTC sensor fault E73 on washer-dryer; hot air process temperature signal out of range..
What is the root cause of Faure error code E73?
The primary root cause for Faure code E73 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Drying air duct NTC sensor open or shorted, thick lint blanket insulating sensor tip, or overheated wiring harness near drying heater box..
How do I fix or resolve Faure error code E73?
To resolve error code E73: Dismantle upper drying heater duct. Clean lint from sensor tip. Measure NTC resistance (4.8–6.0 kΩ at 20°C). Replace if out of range. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E73 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E73 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Drying air duct NTC sensor open or shorted, thick lint blanket insulating sensor tip, or overheated wiring harness near drying heater box. must be inspected or replaced.
How do I test electrical resistance for Faure code E73 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Faure code E73?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?