Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Bosch E73
FAQ TREEWhat does error code E73 mean on a Bosch appliance?
Bosch error code E73 indicates: Bosch Serie 6 / Serie 8 / HomeProfessional AutoClean SelfCleaning Condenser: Condenser NTC sensor fault E73; temperature sensor on refrigerant condenser coil signal open or short-circuit..
What is the root cause of Bosch error code E73?
The primary root cause for Bosch code E73 is: On Bosch tumble dryers: Dislodged sensor clip on condenser copper bend, open lead wire in lower harness, or sensor drift due to thermal cycling..
How do I fix or resolve Bosch error code E73?
To resolve error code E73: Measure condenser NTC sensor resistance (nominal ~10 kΩ at 25°C, ~3.6 kΩ at 50°C). Check clip attachment to copper tube. Replace NTC if out of spec. Turn cycle selector to 6 o'clock, press and hold Start/Pause, rotate selector to 7 o'clock, release button, return to Off.
Is it safe to clear Bosch error code E73 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E73 persists, the physical component causing On Bosch tumble dryers: Dislodged sensor clip on condenser copper bend, open lead wire in lower harness, or sensor drift due to thermal cycling. must be inspected or replaced.
How do I test electrical resistance for Bosch code E73 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Bosch code E73?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



