OFFICIAL FAULT CODEE01
Bosch
Bosch // OFFICIAL DIAGNOSTIC BENCH

Bosch E01

DishwasherElectronic Control Board (PCB) & Bus Communications
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code E01:SiemensE01ElectroluxE01AEGE01CandyE01V-ZugE01HooverE01ZanussiE01Arthur MartinE01GaggenauE01SchulthessE01

Symptom / Description

FAULT

Internal power module fault / Program ends / Power supply or pump switching faulty

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

Electrical connection to pumps interrupted / Voltage drops due to faulty power connection / Power module defective (internal pump control)

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect 230V mains power for 3 minutes. 2. Inspect wire harness and edge connectors on control board for loose pins or oxidation. 3. Inspect mechanical linkages and sensors associated with subsystem. 4. Reset: Press and hold Start/Reset for 3 to 5 seconds until display shows 0:01. Turn dial to OFF, wait 15 seconds, turn back ON and run rinse cycle.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Bosch Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLElectronic Control Board (PCB) & Bus CommunicationsDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Low-voltage rails: +5.0V DC (Logic), +12.0V DC (Relays), +3.3V DC (MCU). Relay coils: 200Ω–450Ω.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:PCB Power Supply Rails & DC Bus Filter Capacitors
Test Pins & Connections
PROBE (+)
PROBE (-)
Across SMPS output electrolytic capacitors on low-voltage side (test bench verification)
Tolerance & Diagnostic CriteriaDC rail ripple must remain <50mV. Direct continuity (0Ω) across DC bus rails indicates dead short.
1. Pre-Intervention Electrical Safety Protocols
  • !High-Voltage Safety Protocol: Disconnect 230V power before unplugging edge connectors or removing PCB.
  • !High Voltage DC Warning: Wait at least 5 minutes for SMPS and inverter filter capacitors (up to 380V DC) to discharge safely.
  • !Electrostatic Discharge (ESD): Ground yourself to the metal chassis or wear an antistatic wrist strap before touching circuit tracks.
3. Preliminary Mechanical & Visual Checks
  • Inspect PCB tracks with a magnifying glass for blown triacs, darkened copper tracks, or cold solder joints on power relays.
  • Check electrolytic capacitors for bulging tops or leaked electrolyte residue around pins.
  • Verify edge connector locking clips are intact and pins are free of vibration fretting corrosion.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Bosch E01

FAQ TREE
What does error code E01 mean on a Bosch appliance?

Bosch error code E01 indicates: Internal power module fault / Program ends / Power supply or pump switching faulty.

What is the root cause of Bosch error code E01?

The primary root cause for Bosch code E01 is: Electrical connection to pumps interrupted / Voltage drops due to faulty power connection / Power module defective (internal pump control).

How do I fix or resolve Bosch error code E01?

To resolve error code E01: 1. Disconnect 230V mains power for 3 minutes. 2. Inspect wire harness and edge connectors on control board for loose pins or oxidation. 3. Inspect mechanical linkages and sensors associated with subsystem. 4. Reset: Press and hold Start/Reset for 3 to 5 seconds until display shows 0:01. Turn dial to OFF, wait 15 seconds, turn back ON and run rinse cycle.

Is it safe to clear Bosch error code E01 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Bosch code E01 persists, the physical component causing Electrical connection to pumps interrupted / Voltage drops due to faulty power connection / Power module defective (internal pump control) must be inspected or replaced.

How do I test electrical resistance for Bosch code E01 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test PCB Power Supply Rails & DC Bus Filter Capacitors across Across SMPS output electrolytic capacitors on low-voltage side (test bench verification). Expected nominal reading is Low-voltage rails: +5.0V DC (Logic), +12.0V DC (Relays), +3.3V DC (MCU). Relay coils: 200Ω–450Ω.. Tolerance: DC rail ripple must remain <50mV. Direct continuity (0Ω) across DC bus rails indicates dead short..

What safety protocol must be followed before servicing Bosch code E01?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // BOSCH

Related Bosch Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E02Heating Element, Thermostat & Safety Fuse
Operation without heating / Operation without zeolite drying system
Inspect Protocol
E03Heating Element, Thermostat & Safety Fuse
Temperature control / Overheating / Operation without auxiliary drying system / Operation wi...
Inspect Protocol
E04Heating Element, Thermostat & Safety Fuse
Flow exchanger motor triac faulty (appliance stops, no function possible)
Inspect Protocol
E05Drainage System & Drain Pump
Program interruption (drain)
Inspect Protocol
E06Drive Motor, Inverter & Tachometer Sensor
Door Hall sensor error / Stops in current position, appliance is without function
Inspect Protocol
E07Heating Element, Thermostat & Safety Fuse
Heating error, operation without additional drying system (applies only to appliances with z...
Inspect Protocol
E08Drainage System & Drain Pump
Program continues without heating, or heating works but with insufficient water for circulat...
Inspect Protocol
E09Heating Element, Thermostat & Safety Fuse
Heating circuit or electrical water heating circuit interrupted (resistance, cables, safety ...
Inspect Protocol
E10Heating Element, Thermostat & Safety Fuse
Bosch E10: Water/air heating failure in Dishwasher; heating circuit does not reach set tempe...
Inspect Protocol
E11NTC Temperature Sensor & Thermistor
Bosch E11: NTC temperature sensor signal out of range (open or short circuit) in Dishwasher.
Inspect Protocol
E13Water Inlet Valve, Aquastop & Flowmeter
The appliance detects a water temperature > 75 °C and turns off the heater
Inspect Protocol
E14NTC Temperature Sensor & Thermistor
Water Fill Error / Reed Switch Fault
Inspect Protocol
E15Drainage System & Drain Pump
Aquastop Anti-flood active
Inspect Protocol
E16Drainage System & Drain Pump
Water loading (impulses from flow meter) without solenoid valve control or appliance recogni...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy