Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure I64
FAQ TREEWhat does error code I64 mean on a Faure appliance?
Faure error code I64 indicates: Faure FDF Series / Clean&Dry / MaxiWash Dishwasher: Heating element relay contacts welded or continuous heat signal i64 detected during initial cold pre-wash phase..
What is the root cause of Faure error code I64?
The primary root cause for Faure code I64 is: On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: Safety heater relay on main control board stuck closed prior to cycle start, or feedback sensing resistor network shorted to VCC..
How do I fix or resolve Faure error code I64?
To resolve error code I64: Measure contact resistance across relay normally-open contacts with power disconnected (must be open circuit / infinite resistance ∞ Ω). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code I64 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code I64 persists, the physical component causing On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: Safety heater relay on main control board stuck closed prior to cycle start, or feedback sensing resistor network shorted to VCC. must be inspected or replaced.
How do I test electrical resistance for Faure code I64 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Immersion / Air Heating Element & Klixon Thermostat across Between element terminals (unwired). Insulation to earth casing: >20MΩ (OL). Expected nominal reading is 25Ω–28Ω (230V / 2000W) / <0.5Ω (Safety Klixon closed). Tolerance: Formula R = V²/P (±5%). Any earth leakage reading below 2MΩ will trip the domestic 30mA RCD breaker..
What safety protocol must be followed before servicing Faure code I64?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?