Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure I70
FAQ TREEWhat does error code I70 mean on a Faure appliance?
Faure error code I70 indicates: Faure FDF Series / Clean&Dry / MaxiWash Dishwasher: Wash tub NTC temperature thermistor open or short circuit i70; temperature measurement circuit inoperative..
What is the root cause of Faure error code I70?
The primary root cause for Faure code I70 is: On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: NTC sensor internal pellet open or shorted (nominal 4.8–6.0 kΩ at 20°C; ~1.2 kΩ at 60°C), broken wiring harness in door hinge bend, or plug loose..
How do I fix or resolve Faure error code I70?
To resolve error code I70: Measure NTC resistance directly at sensor terminals (4.8–6.0 kΩ at 20°C). Check continuity of 2-wire harness through door hinge flex point. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code I70 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code I70 persists, the physical component causing On Faure (Faure FDF Series / Clean&Dry / MaxiWash Dishwasher) models: NTC sensor internal pellet open or shorted (nominal 4.8–6.0 kΩ at 20°C; ~1.2 kΩ at 60°C), broken wiring harness in door hinge bend, or plug loose. must be inspected or replaced.
How do I test electrical resistance for Faure code I70 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Faure code I70?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



