Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEi70
Airlux
Airlux // OFFICIAL DIAGNOSTIC BENCH

Airlux i70

DishwasherNTC Temperature Sensor & Thermistor
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Other Brands Sharing Code i70:ElectroluxI70AEGI70ZanussiI70Arthur MartinI70SchulthessI70CastorI70FaureI70FavoritI70ForsI70MerkerI70

Symptom / Description

FAULT

Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code i70 registered by the microcomputer controller. Sump water temperature sensor NTC open or short circuit.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Airlux appliances engineered with Optima dual-arm spray hydraulics, electronic anti-leak float detection, and low-consumption BLDC wash motor: temperature sensor NTC open or short-circuit. Metrological tolerance verification: NTC 10 kOhms at 25C (1.2 kOhms at 80C)..

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure NTC probe resistance; replace if out of spec. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold the Start/Reset button for 4 seconds until the program indicator light flashes and the drain pump runs for 30 seconds to empty the sump. Switch power off and on again.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Airlux Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Airlux I70

FAQ TREE
What does error code I70 mean on a Airlux appliance?

Airlux error code I70 indicates: Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code i70 registered by the microcomputer controller. Sump water temperature sensor NTC open or short circuit..

What is the root cause of Airlux error code I70?

The primary root cause for Airlux code I70 is: On Airlux appliances engineered with Optima dual-arm spray hydraulics, electronic anti-leak float detection, and low-consumption BLDC wash motor: temperature sensor NTC open or short-circuit. Metrological tolerance verification: NTC 10 kOhms at 25C (1.2 kOhms at 80C)...

How do I fix or resolve Airlux error code I70?

To resolve error code I70: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure NTC probe resistance; replace if out of spec. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold the Start/Reset button for 4 seconds until the program indicator light flashes and the drain pump runs for 30 seconds to empty the sump. Switch power off and on again.

Is it safe to clear Airlux error code I70 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Airlux code I70 persists, the physical component causing On Airlux appliances engineered with Optima dual-arm spray hydraulics, electronic anti-leak float detection, and low-consumption BLDC wash motor: temperature sensor NTC open or short-circuit. Metrological tolerance verification: NTC 10 kOhms at 25C (1.2 kOhms at 80C).. must be inspected or replaced.

How do I test electrical resistance for Airlux code I70 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Airlux code I70?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // AIRLUX

Related Airlux Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

AL01NTC Temperature Sensor & Thermistor
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code AL01 registered by...
Inspect Protocol
AL02Water Level Pressure Switch & Air Dome
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code AL02 registered by...
Inspect Protocol
AL03Water Level Pressure Switch & Air Dome
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code AL03 registered by...
Inspect Protocol
E7Water Level Pressure Switch & Air Dome
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code E7 registered by t...
Inspect Protocol
i10Water Level Pressure Switch & Air Dome
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code i10 registered by ...
Inspect Protocol
i20Water Level Pressure Switch & Air Dome
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code i20 registered by ...
Inspect Protocol
i30Water Level Pressure Switch & Air Dome
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code i30 registered by ...
Inspect Protocol
i40Water Level Pressure Switch & Air Dome
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code i40 registered by ...
Inspect Protocol
i50Water Level Pressure Switch & Air Dome
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code i50 registered by ...
Inspect Protocol
i60Water Level Pressure Switch & Air Dome
Airlux Optima / Silence 44dB Integrated Dishwasher: Diagnostic fault code i60 registered by ...
Inspect Protocol
LNTC Temperature Sensor & Thermistor
Airlux Élite / Domino / Vision Induction and Aspirating Cooktop: Diagnostic fault code L reg...
Inspect Protocol
L3NTC Temperature Sensor & Thermistor
Airlux Climatisation Réversible Inverter & Heat Pump System: Diagnostic fault code L3 regist...
Inspect Protocol
LcNTC Temperature Sensor & Thermistor
Airlux Climatisation Réversible Inverter & Heat Pump System: Diagnostic fault code Lc regist...
Inspect Protocol
LdNTC Temperature Sensor & Thermistor
Airlux Climatisation Réversible Inverter & Heat Pump System: Diagnostic fault code Ld regist...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy