Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEER10
Favorit
Favorit // OFFICIAL DIAGNOSTIC BENCH

Favorit ER10

OvenNTC Temperature Sensor & Thermistor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Other Brands Sharing Code ER10:BrandtER10De DietrichER10FAGORER10SauterER10AirluxER10ArdoER10AtlanticER-10ElicaER10FaberER10IlveER10

Symptom / Description

FAULT

Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER10 registered by the microcomputer controller. Built-in oven power control board Darlington relay driver IC output channel breakdown (code ER10)

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Favorit SwissLine and European precision appliances built for high durability engineered with PT1000 platinum RTD probe (1080 Ω at 20°C), 2400W convection circular element (22-25 Ω), radial exhaust cooling turbine (160-220 Ω), and motorized door interlock latch: relay inductive back-EMF spike damaged open-collector transistor stage in ULN2003 driver array. Metrological tolerance verification: driver output pin resistance to ground must be >50 kΩ unasserted; short to ground (<10 Ω) indicates blown IC.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: de-energize oven, measure resistance between driver IC output pins and ground with ohmmeter, replace PCB if shorted. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature knob to Off. Press and hold Clock and Stop buttons for 5 seconds until confirmation tone sounds, wiping error state from EEPROM.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Favorit Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Favorit ER10

FAQ TREE
What does error code ER10 mean on a Favorit appliance?

Favorit error code ER10 indicates: Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER10 registered by the microcomputer controller. Built-in oven power control board Darlington relay driver IC output channel breakdown (code ER10).

What is the root cause of Favorit error code ER10?

The primary root cause for Favorit code ER10 is: On Favorit SwissLine and European precision appliances built for high durability engineered with PT1000 platinum RTD probe (1080 Ω at 20°C), 2400W convection circular element (22-25 Ω), radial exhaust cooling turbine (160-220 Ω), and motorized door interlock latch: relay inductive back-EMF spike damaged open-collector transistor stage in ULN2003 driver array. Metrological tolerance verification: driver output pin resistance to ground must be >50 kΩ unasserted; short to ground (<10 Ω) indicates blown IC..

How do I fix or resolve Favorit error code ER10?

To resolve error code ER10: Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: de-energize oven, measure resistance between driver IC output pins and ground with ohmmeter, replace PCB if shorted. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature knob to Off. Press and hold Clock and Stop buttons for 5 seconds until confirmation tone sounds, wiping error state from EEPROM.

Is it safe to clear Favorit error code ER10 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Favorit code ER10 persists, the physical component causing On Favorit SwissLine and European precision appliances built for high durability engineered with PT1000 platinum RTD probe (1080 Ω at 20°C), 2400W convection circular element (22-25 Ω), radial exhaust cooling turbine (160-220 Ω), and motorized door interlock latch: relay inductive back-EMF spike damaged open-collector transistor stage in ULN2003 driver array. Metrological tolerance verification: driver output pin resistance to ground must be >50 kΩ unasserted; short to ground (<10 Ω) indicates blown IC. must be inspected or replaced.

How do I test electrical resistance for Favorit code ER10 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Favorit code ER10?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // FAVORIT

Related Favorit Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

ER01NTC Temperature Sensor & Thermistor
Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER0...
Inspect Protocol
ER02NTC Temperature Sensor & Thermistor
Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER0...
Inspect Protocol
ER03NTC Temperature Sensor & Thermistor
Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER0...
Inspect Protocol
ER04NTC Temperature Sensor & Thermistor
Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER0...
Inspect Protocol
ER05NTC Temperature Sensor & Thermistor
Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER0...
Inspect Protocol
ER06NTC Temperature Sensor & Thermistor
Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER0...
Inspect Protocol
ER07NTC Temperature Sensor & Thermistor
Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER0...
Inspect Protocol
ER08NTC Temperature Sensor & Thermistor
Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER0...
Inspect Protocol
ER09NTC Temperature Sensor & Thermistor
Favorit SwissBake / CombiSteam Built-in Pyrolytic Convection Oven: Diagnostic fault code ER0...
Inspect Protocol
F01_RFRefrigeration Compressor, Defrost Heater & PTC Relay
Favorit BioFresh / SwissCool Total NoFrost Inverter Refrigerator: Diagnostic fault code F01_...
Inspect Protocol
F02_RFRefrigeration Compressor, Defrost Heater & PTC Relay
Favorit BioFresh / SwissCool Total NoFrost Inverter Refrigerator: Diagnostic fault code F02_...
Inspect Protocol
F03_RFRefrigeration Compressor, Defrost Heater & PTC Relay
Favorit BioFresh / SwissCool Total NoFrost Inverter Refrigerator: Diagnostic fault code F03_...
Inspect Protocol
F04_RFRefrigeration Compressor, Defrost Heater & PTC Relay
Favorit BioFresh / SwissCool Total NoFrost Inverter Refrigerator: Diagnostic fault code F04_...
Inspect Protocol
F05_RFRefrigeration Compressor, Defrost Heater & PTC Relay
Favorit BioFresh / SwissCool Total NoFrost Inverter Refrigerator: Diagnostic fault code F05_...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy