Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEE16
Gaggenau
Gaggenau // OFFICIAL DIAGNOSTIC BENCH

Gaggenau Dishwasher E16

DishwasherDrainage System & Drain Pump
Premium built-in dishwasher with open illuminated stainless steel interior and precision spray arms
Dishwasher
Select Appliance Type
0ms Instant Telemetry Switch
BSH Group: Equivalent Code Across OEM Group Brands
BSH Electronic Architecture (Bosch / Siemens / Neff / Gaggenau)
BoschE16SiemensE16NeffE16
Other Brands Sharing Code E16:SamsungE16LGE16BekoE16HaierE16CandyE16V-ZugE16HooverE16

Symptom / Description

FAULT

Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Uncontrolled water inflow / solenoid valve leak E16; water continually enters tub even when inlet valve is de-energized.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Gaggenau dishwashers: Mechanically jammed AquaStop solenoid valve seat (limescale or sand grain), or shorted inlet triac on power module.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Turn off water tap immediately. Check for 230V AC at AquaStop when powered off; if present, replace power board. If 0V, replace AquaStop inlet hose. Press and hold illuminated Start key for 4 seconds until '0:01' abort confirms, close door for final drainage, power off.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Gaggenau Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

SWISS ATELIER TECHNICAL BLUEPRINT // 2026 SCHEMATIC STANDARD

Hydraulic & Drainage Loop

Drain Pump M2, Impeller Chamber, Sump Filter & Analog Pressostat

CALIBRATED TEST POINTS (TP1 / TP2)
ACTIVE MULTIMETER BENCH
MAIN PCB CONTROLLER32-BIT MCUFIRMWARE v26.4SOLID-STATE RELAYTRIAC TY1 // 16A 600V230V AC MAINSLINE FILTER L-NJ1J2TP1TP2PRECISION BENCH METERAUTO-RANGE ΩCAT III168.4 ΩVΩCOMDRAIN PUMP M2DRAIN OUTFLOWRATED COIL: 150-280Ω
Target Component
Drain Pump Motor Stator Coils
Nominal Resistance / Test Range
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)
Test Harness Pins
Across pump motor spade terminals (L-N unclipped)
Diagnostic Verification Rule
Measure coil resistance unplugged. If OL (open loop) or < 50 Ω (shorted), replace pump assembly.
CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDrainage System & Drain PumpDishwasher
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Drain Pump Motor Stator Coils
Test Pins & Connections
PROBE (+)
PROBE (-)
Across pump motor spade terminals (L-N unclipped)
Tolerance & Diagnostic Criteria±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Isolate 230V mains power before accessing the lower pump housing.
  • !Prepare a shallow basin and absorption towels: expect 3 to 10 liters of stagnant trapped water upon filter opening.
  • !Beware of sharp foreign objects (broken glass, needles, screws) trapped inside the impeller cavity.
3. Preliminary Mechanical & Visual Checks
  • Unscrew coin trap filter and clear all foreign debris (coins, hairpins, bra underwires).
  • Rotate pump impeller manually: synchronous magnetic rotors should snap cleanly in 90° intervals without jamming.
  • Check drain hose for kinks, blockages, or unpunched sink spigots; verify drain height is between 65cm and 100cm.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Gaggenau E16

FAQ TREE
What does error code E16 mean on a Gaggenau appliance?

Gaggenau error code E16 indicates: Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Uncontrolled water inflow / solenoid valve leak E16; water continually enters tub even when inlet valve is de-energized..

What is the root cause of Gaggenau error code E16?

The primary root cause for Gaggenau code E16 is: On Gaggenau dishwashers: Mechanically jammed AquaStop solenoid valve seat (limescale or sand grain), or shorted inlet triac on power module..

How do I fix or resolve Gaggenau error code E16?

To resolve error code E16: Turn off water tap immediately. Check for 230V AC at AquaStop when powered off; if present, replace power board. If 0V, replace AquaStop inlet hose. Press and hold illuminated Start key for 4 seconds until '0:01' abort confirms, close door for final drainage, power off.

Is it safe to clear Gaggenau error code E16 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Gaggenau code E16 persists, the physical component causing On Gaggenau dishwashers: Mechanically jammed AquaStop solenoid valve seat (limescale or sand grain), or shorted inlet triac on power module. must be inspected or replaced.

How do I test electrical resistance for Gaggenau code E16 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..

What safety protocol must be followed before servicing Gaggenau code E16?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

What does Gaggenau error code E16 mean on a Dishwasher?

Gaggenau error code E16 on a Dishwasher indicates: Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Uncontrolled water inflow / solenoid valve leak E16; water continually enters tub even when inlet valve is de-energized.. Primary cause: On Gaggenau dishwashers: Mechanically jammed AquaStop solenoid valve seat (limescale or sand grain), or shorted inlet triac on power module.. Recommended solution: Turn off water tap immediately. Check for 230V AC at AquaStop when powered off; if present, replace power board. If 0V, replace AquaStop inlet hose. Press and hold illuminated Start key for 4 seconds until '0:01' abort confirms, close door for final drainage, power off..

What does Gaggenau error code E16 mean on a Tumble Dryer?

Gaggenau error code E16 on a Tumble Dryer indicates: Gaggenau 200 Series self-cleaning condenser heat pump dryer: Exhaust air temperature safety cutout E16; exhaust duct sensor exceeds safety temperature limit (> 95°C).. Primary cause: On Gaggenau tumble dryers: Severely restricted exhaust air outlet, crushed flexible exhaust vent hose, or jammed front blower fan wheel.. Recommended solution: Inspect external exhaust venting for clogs or bird nests. Verify front blower fan spins smoothly. Measure exhaust NTC resistance (~10 kΩ at 25°C). Turn solid rotary knob to 6 o'clock, hold Start button, advance knob to position 7, release and return to Off..

What does Gaggenau error code E16 mean on a Washing Machine?

Gaggenau error code E16 on a Washing Machine indicates: Gaggenau 200 Series automatic dosing BLDC inverter washing machine: Door interlock open fault E16; appliance cannot start wash program because door latch contacts remain unmade.. Primary cause: On Gaggenau washers: Laundry trapped between door glass and rubber bellows, worn mechanical latch strike hook, or open circuit in PTC door lock coil.. Recommended solution: Press door firmly until it clicks. Inspect door hook for mechanical damage. Measure resistance across door lock terminals 1 and 3 (nominal ~180–240 Ω). Turn solid rotary dial to Off, hold Option/Enter key while rotating dial to Spin cycle, wait for service menu, return to Off..

Community Verification

COMMUNITY

Did this solution resolve the issue?

Gaggenau E16 — Multi-Appliance Technical Reference

Verified OEM diagnostic specifications across all appliance systems sharing this fault code.

Gaggenau E16 — Dishwasher

[ACTIVE]
Symptom / Description:

Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Uncontrolled water inflow / solenoid valve leak E16; water continually enters tub even when inlet valve is de-energized.

Root Cause:

On Gaggenau dishwashers: Mechanically jammed AquaStop solenoid valve seat (limescale or sand grain), or shorted inlet triac on power module.

Repair Instructions:

Turn off water tap immediately. Check for 230V AC at AquaStop when powered off; if present, replace power board. If 0V, replace AquaStop inlet hose. Press and hold illuminated Start key for 4 seconds until '0:01' abort confirms, close door for final drainage, power off.

Gaggenau E16 — Dryer

Symptom / Description:

Gaggenau 200 Series self-cleaning condenser heat pump dryer: Exhaust air temperature safety cutout E16; exhaust duct sensor exceeds safety temperature limit (> 95°C).

Root Cause:

On Gaggenau tumble dryers: Severely restricted exhaust air outlet, crushed flexible exhaust vent hose, or jammed front blower fan wheel.

Repair Instructions:

Inspect external exhaust venting for clogs or bird nests. Verify front blower fan spins smoothly. Measure exhaust NTC resistance (~10 kΩ at 25°C). Turn solid rotary knob to 6 o'clock, hold Start button, advance knob to position 7, release and return to Off.

Gaggenau E16 — Washing Machine

Symptom / Description:

Gaggenau 200 Series automatic dosing BLDC inverter washing machine: Door interlock open fault E16; appliance cannot start wash program because door latch contacts remain unmade.

Root Cause:

On Gaggenau washers: Laundry trapped between door glass and rubber bellows, worn mechanical latch strike hook, or open circuit in PTC door lock coil.

Repair Instructions:

Press door firmly until it clicks. Inspect door hook for mechanical damage. Measure resistance across door lock terminals 1 and 3 (nominal ~180–240 Ω). Turn solid rotary dial to Off, hold Option/Enter key while rotating dial to Spin cycle, wait for service menu, return to Off.

SEMANTIC KNOWLEDGE GRAPH // GAGGENAU

Related Gaggenau Dishwasher Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E17Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: High water inlet pressur...
Inspect Protocol
E18Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Low water flow inlet tim...
Inspect Protocol
E19Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Dispenser actuator / hea...
Inspect Protocol
E20Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Circulation pump BLDC wi...
Inspect Protocol
E21Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Circulation pump motor j...
Inspect Protocol
E22Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Sump filter blocked / re...
Inspect Protocol
E23Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Drain pump winding resis...
Inspect Protocol
E24Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Drain hose obstruction /...
Inspect Protocol
E25Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Drain pump impeller lock...
Inspect Protocol
E26Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Water switch diverter va...
Inspect Protocol
E27Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Mains undervoltage detec...
Inspect Protocol
E28Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Turbidity AquaSensor opt...
Inspect Protocol
E29Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Mains supply frequency o...
Inspect Protocol
E30Dishwasher
Drainage System & Drain Pump
Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Mains overvoltage detect...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy