Haier Ed — Dishwasher
[ACTIVE]Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Detergent dispenser actuator fault Ed; tablet door flap fails to trip open during primary wash cycle.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Open dispenser wax motor or solenoid actuator coil (~1.5–3.0 kΩ), mechanical latch jam, or broken door wiring.
Remove inner door panel. Measure dispenser actuator coil resistance (~1.5–3.0 kΩ). Check spring-loaded flap latch for smooth movement. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.